FIREPLACE INSTALLATION

To determine the safest and most efcient location
for the replace, you must take into consideration
the following guidelines:
1. The location must allow for proper clearances
(see Figures 1 and 2).
2. Consider a location where the replace will
not be affected by drafts, air conditioning
ducts, windows or doors.
3. A location that avoids the cutting of joists or
roof rafters will make installation easier.
4. An outside air kit is available with this replace
(see Optional Outside Air Kit on page 6).


Back and sides of replace 3/4" minimum*
Floor** 0" minimum
Perpendicular wall to opening 12" minimum
Top spacers 0" minimum
Mantel clearances
see Mantels, page 5
Chimney outer pipe surface 1" minimum
* Not required at nailing anges
** See step 2 of Framing
-
quired air spaces with insulation
or other materials.

Residential Installation
The minimum height of the chimney, measured
from the base of the replace to the ue gas outlet
of the termination, is 14.5 feet for straight ue or
a ue with one elbow set. The maximum distance
between elbows is 6 feet. For systems with two
elbow sets, the minimum height is 22 feet. The
maximum height of any system is 50 feet. This
measurement includes the replace, chimney sec-
tions and the height of the termination assembly
at the level of the ue gas outlet (see Figure 18,
page 11).

Outdoor Installation
The minimum height of the chimney, measured
from the base of the replace to the ue gas outlet
of the termination, is 8 feet (minimum of 4 feet
of chimney pipe sections required for outdoor
installation).

1. Frame the opening for the replace using the
dimensions shown in Figures 1 and 2.
2. If the replace is to be installed directly on
carpeting, tile (other than ceramic) or any
combustible material other than wood oor-
ing, the replace must be installed upon a
metal or wood panel extending the full width
and depth of the replace.
3. Set the replace directly in front of this open-
ing and slide the unit back until the nailing
anges touch the side framing.
4. Check the level of the replace and shim with
sheet metal if necessary.
5. Before securing replace to prepared fram-
ing, the ember protector (provided) must
be placed between the hearth extension (not
supplied) and under the bottom front edge
of the replace to protect against glowing
embers falling through. If the replace is to be
installed on a raised platform, a Z-type ember
protector (not supplied) must be fabricated to
t your required platform height. The ember
protector should extend under the replace a
minimum of 1
1
/
2
". The ember protector should
be made of galvanized sheet metal (28 gauge
minimum) to prevent corrosion.
6. Using screws or nails, secure the replace to
the framing through anges located on the
sides of the replace.
23.50”
43.375”
48.25”
Figure 1 - Framing Dimensions
59.264"
19.466"
27.527"
83.830"
MAINTAIN
3
/
4
"
CLEARANCE AT
SIDES AND BACK
OF FIREPLACE
3
/4" CLEARANCE
NOT REQUIRED AT
NAILING FLANGES
Figure 2 - Corner Installation