SPECIFICATIONS
RP30D CGP20(L)
Btu (Variable) 15,000/30,000 10,000/20,000
Type Gas Propane/LP Only Propane/LP Only
Ignition Piezo Piezo
Pressure Regulator Setting 8" W.C. 8" W.C.
Inlet Gas Pressure (inches of water)
Maximum 14" 14"
Minimum 11" 11"
Dimensions, Inches (H x W x D)
Heater 23.5 x 25.9 x 8.0 23.5 x 18.5 x 8.0
Carton 26 x 27.75 x 9.63 26 x 20.5 x 9.63
Weight (pounds)
Heater 30 22
Shipping 35 27
When gas pressure is too low
• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
When gas quality is bad
• pilot will not stay lit
• burner will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.
SERVICE HINTS
CLEANING AND
MAINTENANCE
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep
control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting
and bedding material, sawdust,
cobwebs, etc.
ODS/PILOT AND BURNER
• Use a vacuum cleaner, pressurized air, or
small, soft bristled brush to clean.
CABINET
Air Passageways
• Use a vacuum cleaner or pressurized air
to clean.
Exterior
• Use a soft cloth dampened with a mild
soap and water mixture. Wipe the cabi-
net to remove dust.