Desa ROPANE CONSTRUCTION HEATERS Electric Heater User Manual


 
11
099162
LP-PFA/P 019A150 Model
Air Sensing Switch
(80,000 BTU/Hr Model)
1. Remove upper shell (see
page 10).
2. Clean air sensing switch
paddle. Use soft cloth
moistened with kerosene
or solvent.
IMPORTANT:
Do not scrub. Use gentle
cleaning action. Do not
bend paddle or paddle
arm.
3. Blot paddle dry with a soft
cloth.
4. Replace fan guard and
upper shell.
Air Sensing
Switch
Paddle
Paddle
Arm
Spark Plug
(80,000 BTU/Hr Model)
1. Remove upper shell (see
page 10).
2. Remove fan (see page 10).
3. Remove spark plug cable
from spark plug.
4. Place 11/16" socket onto
spark plug mounting nut.
Spark plug mounting nut
is located on spark plug
threads inside combustion
chamber (see Figures 12
and 14).
5. Loosen and remove spark
plug with 13/16" spark
plug socket. Be careful not
to strike air sensing switch
paddle.
6. Clean and regap spark
plug electrodes. Regap
electrodes to .06/.08 inch.
Gap
Bend Here
To Adjust
Gap
Figure 11 - Air Sensing Switch Location, 80,000 BTU/Hr Model Only
Figure 13 - Spark Plug Gap
Continued
LP-PFA/P 021Spark Plug Nut Location
Spark Plug
Mounting
Nut
Spark Plug
Cable
Spark Plug
Cable
Combustion
Chamber
Ignitor
(150,000 BTU/Hr Model)
1. Make sure gap between
ignitor electrode and
burner nozzle is .13⁄.15".
Access ignitor electrode
from inside combustion
chamber. No other main-
tenance is needed for
ignitor.
Figure 12 - Spark Plug and Spark Plug Mounting Nut Location
on Combustion Chamber