Desa RM60 Electric Heater User Manual


 
6
104672
PORTABLE FORCED AIR HEATER
60,000 Btu/Hr H.S.I. Series
Figure 6 - Pressure Gauge Plug Removal
Relief
Valve
Pressure
Gauge
Plug
Figure 7 - Adjusting Pump Pressure
Pressure
Gauge
Fan
Motor
Figure 3 - Upper Shell Removal
Figure 5 - Air Output, Air Intake, and Lint
Filters
Flush
Setscrew
Motor
Shaft
Figure 4 - Fan Cross Section
Air Intake Filter
Filter End Cover
Fan Guard
Air Output Filter
Lint Filter
Upper
Shell
Fan
Guard
SERVICE
PROCEDURES
UPPER SHELL REMOVAL
1. Remove screws along each side of
heater using 5/16" nut-driver. These
screws attach upper and lower shells
together.
2. Lift upper shell off.
3. Remove fan guard.
FAN
IMPORTANT:
Remove fan from motor
shaft before removing motor from heater.
The weight of the motor resting on the fan
could damage the fan pitch.
1. Remove upper shell (see above).
2. Use 1/8" Allen wrench to loosen set-
screw which holds fan to motor shaft.
3. Slip fan off motor shaft.
4. Clean fan using soft cloth moistened
with kerosene or solvent.
5. Dry fan thoroughly.
6. Replace fan on motor shaft. Place fan
hub flush with end of motor shaft (see
Figure 4).
7. Place setscrew on flat of shaft. Tighten
setscrew firmly (40-50 inch-pounds).
8. Replace fan guard and upper shell.
AIR OUTPUT, AIR INTAKE,
AND LINT FILTERS
1. Remove upper shell (see Upper Shell
Removal).
2. Remove filter end cover screws using
5/16" nut-driver.
3. Remove filter end cover.
4. Replace air output and lint filters.
5. Wash or replace air intake filter (see
Preventative Maintenance Schedule,
page 4).
6. Replace filter end cover.
7. Replace fan guard and upper shell.
IMPORTANT:
Do not oil filters.
PUMP PRESSURE
ADJUSTMENT
1. Remove pressure gauge plug from filter
end cover.
2. Install accessory pressure gauge (part
number HA1180).
3. Start heater (see Operation, page 4).
Allow motor to reach full speed.
4. Using a flat blade screwdriver, adjust
pressure. Turn relief valve to right to
increase the pressure. Turn relief valve
to left to decrease the pressure. Set
pump pressure to 3.4 psi.
5. Stop heater (see Operation, page 4).
6. Remove pressure gauge. Replace pres-
sure gauge plug in filter end cover.
WARNING: Never service
heater while it is plugged in, op-
erating, or hot. Severe burns and
electrical shock can occur.