Desa REM50B Electric Heater User Manual


 
4
102016
PRODUCT
IDENTIFICATION
35/50/70,000 BTU/HR DOMESTIC
PFA/PV 042
Handle
Fuel Cap
Lower Shell
Power Cord
Side Cover
Fuel Tank
Hot Air Outlet
Air Filter
End Cover
Fan Guard
Upper Shell
Flame-Out Control
Reset Button
Figure 1 - Models B50G and REM50B
1. Remove all packing items applied to heater for shipment.
2. Remove all items from carton.
3. Check items for shipping damage. If heater is damaged, promptly inform
dealer where you bought heater.
UNPACKING
The Fuel System: The air pump forces air through the air line. The air is then
pushed through the burner head nozzle. This air causes fuel to lift from the tank.
A fine mist of fuel is sprayed into the combustion chamber.
The Air System: The motor turns the fan. The fan pushes air into and around
the combustion chamber. This air is heated and provides a stream of clean, hot air.
The Ignition System: The electronic ignitor sends voltage to the spark plug.
The spark plug ignites the fuel and air mixture.
The Flame-Out Control System: This system causes the heater to shut down
if the flame goes out.
THEORY OF
OPERATION
THEORY CUTAWAY
PFA/OV 003
Combustion
Chamber
Spark
Plug
Burner
Head
Fan
Motor
Air Pump
Air Intake
Filter
Cool
Air
In
Air
Output
Filter
Air Line
To Burner
Electronic
Ignitor
Fuel
Filter
Nozzle
Fuel
Tank
Clean
Heated
Air Out
Air For Fuel
System
Air For Combustion
And Heating
Fuel
Figure 2 - Cross Section Operational View