Desa REM20PT Electric Heater User Manual


 
www.desatech.com
17116307-01C
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1.
Control knob not fully pressed in
2. Control knob not pressed in
long enough
3. Equipment shutoff valve not
fully open
4. Thermocouple connection
loose at control valve
5. Pilot ame not touching ther-
mocouple, which allows ther-
mocouple to cool, causing
pilot flame to go out. This
problem could be caused by
one or both of the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot
6. Thermocouple damaged
7. Control valve damaged
8. Safety interlock system has
been triggered (thermostat
models only)
1. Burner orice(s) is clogged
2. Inlet gas pressure is too low
1. Manifold pressure is too low
2. Burner orice(s) is clogged
1. Burner orice(s) is clogged or
damaged
2. Burner damaged
3. Gas regulator defective
REMEDY
1. Press in control knob fully
2. After ODS/pilot lights, keep con-
trol knob pressed in 30 seconds
3. Fully open equipment shutoff
valve
4. Hand tighten until snug, then
tighten 1/4 turn more
5. A) Contact local natural or
propane/LP gas company
B) Clean ODS/pilot (see
Cleaning and Maintenance,
page 15) or replace ODS/pilot
assembly
6. Replace pilot assembly
7. Replace control valve
8. Wait one minute for safety in-
terlock system to reset. Repeat
ignition operation
1. Clean burner orice(s) (see
Cleaning and Maintenance,
page 15) or replace burner
orice(s)
2. Contact local natural or pro-
pane/LP gas company
1. Contact local natural or pro-
pane/LP gas company
2. Clean burner orice(s) (see
Cleaning and Maintenance,
page 15) or replace burner
orice(s)
1. Clean burner orice(s) (see
Cleaning and Maintenance,
page 15) or replace burner
orice(s)
2. Replace burner
3. Replace gas regulator
OBSERVED PROBLEM
ODS/pilot lights but flame
goes out when control knob is
released
Burner(s) does not light after
ODS/pilot is lit
Delayed ignition of burner(s)
Burner backring during com-
bustion