Desa RCP80 Gas Heater User Manual


 
10
099684
MAINTENANCE
WARNING
Never attempt to service heater while it is connected to
propane supply, operating, or hot. Severe burns can occur.
SYMPTOM
Pilot fails
to light
Pilot lights
but goes
out when
automatic
control valve
button
is released
Burn rate
is low
POSSIBLE CAUSE
1. Propane supply valve closed
on propane tank(s)
2. Excess flow check valve
closed
3. Air in gas line
4. Blockage in pilot orifice
5. Piezo ignition system not
sparking
1. Not enough warm up time
2. Low gas pressure
3. Thermocouple loose or
needs to be replaced
4. Automatic control valve
needs to be replaced
1. Main burner valve not fully
open
2. Plugged gas orifice
3. Low gas pressure
4. Low fuel supply
REMEDY
1. Open propane supply valve
slowly.
2. Close propane supply valve on
propane tank and reopen slowly.
3. Allow several minutes to purge
air with automatic control
valve button depressed.
4. Replace pilot orifice.
5. Adjust ignitor electrode gap to
.120". Check wire lead for
damage. Replace piezo ignitor
and/or ignitor electrode as
necessary.
1. Relight, hold automatic control
valve button in 45 seconds.
2. Check propane tank(s) for
proper gas supply.
3. Tighten connection or replace
thermocouple.
4. Replace automatic control
valve.
1. Fully open main burner valve
by turning the valve handle
towards HIGH position until it
stops.
2. Replace gas orifice.
3. Check gas supply; check
regulator output.
4. Consult propane gas supplier.
TROUBLE-
SHOOTING
WARNING
Never attempt to service heater while it is connected to
propane supply, operating, or hot. Severe burns can occur.
1. Keep heater clean.
2. Inspect heater before each use. Check connections for leaks. Apply mixture of
liquid soap and water to connections. Bubbles forming show a leak that must be
corrected. Correct all leaks at once.
3. Inspect hose/regulator assembly before each use. If hose is highly worn or cut,
replace.
4. Have heater inspected yearly by service person.