Desa RCP275 Gas Heater User Manual


 
7
099156
6. Close propane supply valve.
Figure 4 - Main Burner Valve Handle, Automatic Control Valve Button, and
Piezo Ignitor Button Locations
LP-PFA/OV 006Gas Controls-TrashCan
Piezo Ignitor
Button
Main Burner
Valve Handle
Continued
5. Check all connections for leaks. Apply mixture of liquid soap and water to gas
joints. Bubbles forming show a leak that must be corrected.
OPERATION
Automatic
Control Valve
Button
!
WARNING
Never use an open flame to check for a leak. Apply a mixture
of liquid soap and water to all joints. Bubbles forming show a
leak that must be corrected. Correct all leaks at once.
!
WARNING
Review and understand the warnings in the Safety Informa-
tion Section. They are needed to safely operate this heater.
Follow all local codes when using this heater.
To Start Heater
1. Follow all installation, ventilation, and safety information.
2. Locate heater on stable and level surface. Make sure strong drafts do not blow
on heater.
!
WARNING
Fully close main burner valve before lighting pilot. If not,
severe burns can occur. Do this by turning valve handle
towards the OFF position until it stops.
3. Open propane supply valve on propane tank(s) slowly.
Note:
If not opened
slowly, excess-flow check valve on propane tank will stop gas flow. If this
happens, close propane supply valve and open again slowly.
4. Push in and hold automatic control valve button (see Figure 4). Push piezo
ignitor button (see Figure 4). You may need to push the piezo ignitor button 3-
8 times until the pilot lights.
Note:
Hose may be filled with air. If so, keep
automatic control valve button pressed and wait 20 seconds before pressing
ignitor button again. When pilot lights, keep automatic control valve button
pushed in. Release button after 30 seconds.