Desa RCP25 Gas Heater User Manual


 
6
101489
INSTALLATION
Inlet Connector
Hose
Figure 4 - Hose and Inlet Connector
1. Provide propane supply system (see Propane Supply, page 5).
2. Connect POL fitting on hose/regulator assembly to propane tank(s). Turn POL
fitting counterclockwise into threads on tank. Tighten firmly using
2.22 cm (7/8 inch) wrench.
IMPORTANT:
Position regulator so that hose
leaving the regulator is in a horizontal position (see Figure 3). This places the
regulator vent in the proper position to protect it from the weather.
WARNING ICON G 001
WARNING
Review and understand the warnings in the Safety Information
Section, pages 2 and 3. They are needed to safely operate this
heater. Follow all local codes when using this heater.
3. Connect hose to inlet connector. Tighten firmly using a wrench.
IMPORTANT:
Use extra hose or piping if needed. Install extra hose or piping
between hose/regulator assembly and propane tank. You must use the regula-
tor supplied with heater.
Propane
Tank
Propane
Supply
Valve
Regulator
Hose
POL Fitting
Figure 3 - Regulator Position
WARNING ICON G 001
WARNING
Test all gas piping and connections for leaks after installing
or servicing. Never use an open flame to check for a leak.
Apply a mixture of liquid soap and water to all joints.
Bubbles forming show a leak. Correct all leaks at once.