Desa NTH70 Fan User Manual


 
10
104976
PORTABLE FORCED AIR HEATERS
Air Output, Air Intake, and Lint
Filters
1. Remove upper shell (see page 8).
2. Remove filter end cover screws using
5/16" nut-driver.
3. Remove filter end cover.
4. Replace air output and lint filters.
5. Wash or replace air intake filter (see
Preventative Maintenance Schedule,
page 6).
6. Replace filter end cover.
7. Replace fan guard and upper shell.
IMPORTANT:
Do not oil filters
Pump Pressure Adjustment
1. Remove pressure gauge plug from filter
end cover.
2. Install accessory pressure gauge (part
number HA1180).
3. Start heater (see Operation, page 5).
Allow motor to reach full speed.
4. Adjust pressure. Turn relief valve to
right to increase pressure. Turn relief
valve to left to decrease pressure. See
specifications below for correct pres-
sure for each model.
5. Remove pressure gauge. Replace pres-
sure gauge plug in filter end cover.
Figure 16 - Air Output, Air Intake, and Lint Filters, 35/50/70,000 Btu/Hr Models
Figure 18 - Pressure Gauge Plug Removal
Pressure
Gauge
Plug
Pressure
Gauge
Figure 19 - Adjusting Pump Pressure
Pump
Pressure
Model (PSI/Bar)
35,000 Btu/Hr 2.9/0.200
50,000 Btu/Hr 4.9/0.338
70,000 Btu/Hr 5.2/0.359
100,000 Btu/Hr 3.9/0.269
150,000 Btu/Hr 4.8/0.331
(35/50/70,000 Btu/Hr Models Shown)
Relief
Valve
SERVICE
PROCEDURES
Continued
Air Intake Filter
Lint Filter
Filter End
Cover
Air Output
Filter
Fan Guard
Air Intake Filter
Filter End
Cover
Lint Filter
Air Output
Filter
Figure 17 - Air Output, Air Intake, and Lint Filters, 100/150,000 Btu/Hr Models
Fan Guard