www.desatech.com
123995-01C26
SPECIFICATIONS
BLUE FLAME MODELS
GWP6
• 4,400/6,000 Btu/hr (Variable)
• Propane/LP Gas
• Piezo Ignition
• Pressure Regulator Setting: 8" W.C.
• Inlet Gas Pressure (inches of water):
Maximum - 14" wc, Minimum - 11" wc
GWN6
• 4,400/6,000 Btu/hr (Variable)
• Natural Gas
• Piezo Ignition
• Pressure Regulator Setting: 3" W.C.
• Inlet Gas Pressure (inches of water):
Maximum - 10.5" wc, Minimum - 4" wc
GWP10, GWP10T, MP10T,
VP1000BTA, WMP10
• 5,000/10,000 Btu/hr (variable)
• Propane/LP Gas
• Piezo Ignition
• Pressure Regulator Setting: 8" W.C.
• Inlet Gas Pressure (inches of water):
Maximum - 14" W.C., Minimum - 11" W.C.
GWN10, GWN10T, MN10T,
VN1000BTA, WMN10
• 5,000/10,000 Btu/hr (variable)
• Natural Gas
• Piezo Ignition
• Pressure Regulator Setting: 3" W.C.
• Inlet Gas Pressure (inches of water):
Maximum - 10.5" W.C., Minimum - 4" W.C.
PLAQUE MODELS
VP5D
• 5,500 Btu/hr
• Propane/LP Gas
• Piezo Ignition
• Pressure Regulator Setting: 8" W.C.
• Inlet Gas Pressure (inches of water):
Maximum - 14" W.C., Minimum - 11" W.C.
VN6D
• 6,000 Btu/hr
• Natural Gas
• Piezo Ignition
• Pressure Regulator Setting: 3" W.C.
• Inlet Gas Pressure (inches of water):
Maximum - 10.5" W.C., Minimum - 4" W.C.
GWRP10, VP10A
• 5,500/10,000 Btu/hr
• Propane/LP Gas
• Piezo Ignition
• Pressure Regulator Setting: 8" W.C.
• Inlet Gas Pressure (inches of water):
Maximum - 14" W.C., Minimum - 11" W.C.
GWRN10, VN10A
• 5,500/10,000 Btu/hr
• Natural Gas
• Piezo Ignition
• Pressure Regulator Setting: 3.0" W.C.
• Inlet Gas Pressure (inches of water):
Maximum - 10.5" W.C., Minimum - 4" W.C.
VP10TA
• 10,000 Btu/hr
• Propane/LP Gas
• Piezo Ignition
• Pressure Regulator Setting: 8" W.C.
• Inlet Gas Pressure (inches of water):
Maximum - 14" W.C., Minimum - 11" W.C.
VN10TA
• 10,000 Btu/hr
• Natural Gas
• Piezo Ignition
• Pressure Regulator Setting: 3.5" W.C.
• Inlet Gas Pressure (inches of water):
Maximum - 10.5" W.C., Minimum - 4" W.C.