Desa M42P(B,H) Indoor Fireplace User Manual


 
www.desatech.com
108795-01V8
PRE-INSTALLATION PREPARATION
Continued
FRAMING
1. Frame appliance enclosure as illustrated
in Figures 7 and 8.
Note: If a wall covering is used to line the
enclosure, then all measurements must
be from the surface of the covering.
2. Place the appliance into the framing and
secure it.
Note: If appliance is to be raised above
oor level, a platform must be built to
support the appliance.
3. Install the supply line to the appliance
using a 1/2" NPT black iron gas line ter-
minating 2
5
/
16
" above the bottom of the
appliance. The gas line must be installed
through the lower left side access point or
alternate access hole in the bottom of the
appliance (see Figure 19, page 13).
4. Repack insulation around the gas line to
cover any remaining openings in the con-
duit sleeve. Prepare the incoming gas line
with teon tape or pipe joint compound
and hook-up incoming gas line to the
exible gas line.
Note: If 1/2" NPT black iron pipe does not
mate with tting at the end of exible gas
line, remove tting and replace with a 37°
are 3/4"-12, 1/2" NPT (female) tting.
WARNING: Whennishing
appliance,donotoverlapcom-
bustiblematerialontotheblack
front face. Brick, tile or other
noncombustiblematerialsmay
beappliedtothefaceprovided
that any gap is between the
material used and the face is
caulkedwithanoncombustible
caulking.
Figure 7 - Rough Opening for Installing
in Wall
B
C
A
M36(B,H),
M36P(B,H)
VM36(B,H),
VM36P(B,H)
M42(B,H),
M42P(B,H)
VM42(B,H),
VM42P(B,H)
A 40
3
/
8
" (102 cm) 44
3
/
8
" (112 cm)
B 21
3
/
8
" (54.3 cm) 23
1
/
8
" (58.7 cm)
C 41
1
/
4
" (104.8 cm) 48
1
/
4
" (122.6 cm)
Figure 8 - Corner Installation Guidelines
A
B
C
D
M36(B,H),
M36P(B,H)
VM36(B,H),
VM36P(B,H)
M42(B,H),
M42P(B,H)
VM42(B,H),
VM42P(B,H)
A 24
1
/
2
" (62.2 cm) 27
9
/
16
" (70 cm)
B 73
7
/
8
" (187.6 cm) 83
7
/
8
" (213 cm)
C 52
3
/
16
" (132.6 cm) 59
5
/
16
" (150.6 cm)
D 17
1
/
4
" (43.8 cm) 19
1
/
2
" (49.5 cm)
These Dimensions Allow for a 3/4"
Clearance at Sides and Back of Fireplace.
However, 0" Clearance is Permitted.
3/4" Clearance Not Required