INSTALLATION
WARNING: A qualified service person must in-
stall heater. Follow all local codes.
CHECK GAS TYPE
Use only the correct type of gas (natural or propane/LP). If your gas
supply is not the correct gas type, do not install heater. Call dealer
where you bought heater for proper type heater.
INSTALLATION ITEMS
Before installing heater, make sure you have the items listed below.
for propane/LP gas, external regulator (supplied by installer)
piping (check local codes)
sealant (resistant to propane/LP gas)
equipment shutoff valve *
ground joint union
test gauge connection *
sediment trap
tee joint
pipe wrench
for natural gas, test gauge connection*
* A CSA design-certified equipment shutoff valve with 1/8" NPT
tap is an acceptable alternative to test gauge connection. The
optional CSA design-certified equipment shutoff valve can be
purchased from your dealer. See Accessories, page 27.
NOTICE: This heater is intended for use as supple-
mental heat. Use this heater along with your primary
heating system. Do not install this heater as your
primary heat source. If you have a central heating
system, you may run systems circulating blower
while using heater. This will help circulate the heat
throughout the house. In the event of a power outage,
you can use this heater as your primary heat source.
CAUTION: This heater creates warm air currents.
These currents move heat to wall surfaces next to
heater. Installing heater next to vinyl or cloth wall
coverings or operating heater where impurities (such
as, but not limited to, tobacco smoke, aromatic
candles, cleaning fluids, oil or kerosene lamps, etc.)
in the air exist, may discolor walls or cause odors.
WARNING: Never install the heater
in a bedroom or bathroom
in a recreational vehicle
where curtains, furniture, clothing, or other flam-
mable objects are less than 36 inches from the
front, top, or sides of the heater
as a fireplace insert
in high traffic areas
in windy or drafty areas
LOCATING HEATER
This heater is designed to be mounted on a wall.
WARNING: Maintain the minimum clearances
shown in Figure 4. If you can, provide greater clear-
ances from floor, ceiling, and joining wall.
Figure 4 - Mounting Clearances As Viewed From Front of Heater
INSTALLATION
Check Gas Type
Installation Items
Locating Heater
You can locate heater on floor, away from a wall. An optional floor
mounting stand is needed. Purchase the floor mounting stand from
your dealer. See Accessories, page 27.
CAUTION: If you install the heater in a home garage
heater pilot and burner must be at least 18 inches
above floor
locate heater where moving vehicle will not hit it
IMPORTANT:
Vent-free heaters add moisture to the air. Although
this is beneficial, installing heater in rooms without enough venti-
lation air may cause mildew to form from too much moisture. See
Air for Combustion and Ventilation, pages 4 through 6. If high
humidity is experienced, a dehumidifier may be used to help lower
the water vapor content in the air.
For convenience and efficiency, install heater
where there is easy access for operation, inspection, and service
in coldest part of room
An optional fan kit is available from your dealer. See Accessories,
page 27. If planning to use fan, locate heater near an electrical outlet.
Minimum
From
Sides Of
Heater
36"
2"
FLOOR
CEILING
Minimum
Minimum To
Top Surface
Of Carpeting
,
Tile Or Other
Combustible
Material
Left
Side
Right
Side
6"