Desa GG30P Gas Heater User Manual


 
www.desatech.com
114683-01B 23
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
building.
• Immediately call your gas supplier from a neighbor’s phone. Fol-
low the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies,
paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes.
POSSIBLE CAUSE
1. Heater burning vapors from
paint, hair spray, glues, etc.
(see IMPORTANT statement
above)
2. Low fuel supply (propane/LP
gas only)
3. Gas leak. See Warning
statement above
1. Not enough fresh air is
available
2. Low line pressure
3. ODS/pilot is pa rtiall y
clogged
1. Gas leak. See Warning
statement above
2. Control valve defective
1. Foreign matter between con
-
trol valve and burner
2. Gas leak. See Warning
statement above
1. Not enough combustion/ven
-
tilation air
OBSERVED PROBLEM
Heater produces unwanted
odors
Heater shuts off in use (ODS
operates)
Gas odor even when control knob
is in OFF position
Gas odor during combustion
Moisture/condensation noticed
on windows
REMEDY
1. Ventilate room. Stop using
odor causing products while
heater is running
2. Refill supply tank
3. Locate and correct all leaks
(see Checking Gas Connec
-
tions, page 13)
1. Open window and/or door for
ventilation
2. Contact local natural or pro
-
pane/LP gas company
3. Clean ODS/pilot (see Cleaning
and Maintenance, page 19)
1. Locate and correct all leaks
(see Checking Gas Connec
-
tions, page 13)
2. Replace control valve
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all leaks
(see Checking Gas Connec
-
tions, page 13)
1. Refer to Air for Combustion
and Ventilation requirements
(page 5)
TROUBLESHOOTING
Continued