Desa FPVF33NR Indoor Fireplace User Manual


 
105270
For more information, visit www.desatech.com
For more information, visit www.desatech.com
9
9
INSTALLATION
Continued
INSTALLATION
Conventional Fireplace Installation (Cont.)
Figure 10 - Installing Cabinet Mantel
Figure 9 - Placing Hearth Base Accessory Against Wall
Electrical Outlet
Hearth
Base
Rigid Gas Line
Gas Line
Access
Hole
Cabinet
Mantel
sory for models VYGF33NRA or VYGF33PRA can only be paired
with the corner hearth base. If mounting fireplace and cabinet or
corner mantel to the floor, an optional G3005 Series Slim Base kit
may be installed.
1. Assemble cabinet mantel, hearth base, and trim accessories.
Assembly instructions are included with each accessory.
2. When installing blower, install a properly grounded, 120 volt
three-prong electrical outlet at fireplace location if an outlet is
not there. If possible, locate outlet so cabinet mantel will cover
it when installed (see Figure 9).
3. Install gas piping to fireplace location. This installation includes
an approved flexible gas line (if allowed by local codes) after
the equipment shutoff valve. The flexible gas line must be the
last item installed on the gas piping. See Installing Gas Piping
to Fireplace Location, pages 12 and 13.
4. Place hearth base accessory against wall at installation loca-
tion. Cut an access hole in hearth top to run flexible gas line to
fireplace (see Figure 9). Make sure to locate access hole so
cabinet mantel will cover it when installed.
Note:
You can
secure base to floor using wood screws. Countersink screw
heads and putty over.
5. Route flexible gas line through access hole in hearth base.
6. Center cabinet mantel on hearth base (see Figure 10). Make
sure mantel is flush against wall.
7. Break off nailing flanges (see Figure 11) with hammer or pliers.
8. Place cardboard or other protective material on top of hearth
base. Carefully set fireplace on protective material, with back
of fireplace inside mantel opening.
9. Attach flexible gas line from fireplace gas regulator to gas sup-
ply. See Connecting Fireplace to Gas Supply, page 13.
10. If blower is installed, route blower electrical cord through ac-
cess holes in either side of fireplace.
Note:
Bushing may be
moved if necessary. Plug electrical cord into electrical outlet.
11. Carefully insert fireplace into cabinet mantel. Be careful not
to scratch or damage hearth base, cabinet mantel, or any lami-
nate trim on hearth base (laminate trim for models
VYGF33PRA and VYGF33NRA only). Remove protective
material from top of hearth base and from front of fireplace (if
any).
Note:
You can secure fireplace to hearth or floor. Open
lower louver. Locate screw holes in bottom of base. Tighten
wood screws through these holes and into hearth or floor.
12. Check all gas connections for leaks. See Checking Gas Con-
nections, page 14.
Figure 11 - Location of Nailing Flanges
Nailing
Flanges
Figure 12 - Inserting Fireplace Into Cabinet Mantel