THERMOSTAT MODELS FAS-3B
AND FAS-5B
FOR YOUR SAFETY
READ BEFORE
LIGHTING
A. This appliance has a pilot which must
be lighted by hand. When lighting the
pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all
around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.
WHAT TO DO IF YOU SMELL
GAS
Do not try to light any appliance.
Do not touch any electric switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
If you cannot reach your gas sup-
plier, call the fire department.
C. Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.
D. Do not use this appliance if any part
has been under water. Immediately call
a qualified service technician to inspect
the appliance and to replace any part
of the control system and any gas con-
trol which has been under water.
WARNING: If you do not fol-
low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information,
column 1.
2. Make sure manual shutoff valve is
fully open.
3. Push in control knob slightly and
turn clockwise to the OFF
position. Be sure that the tempera-
ture setting knob is set at the line
between level 1 and level 7 (see Fig-
ure 19).
4. Wait five minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation in column 1. If you don’t
smell gas, go to the next step.
OFF
ON
PILOT
IGN
1
7
3
5
4
6
2
Figure 19 - Dual Control for Thermostat
Models FAS-3B and FAS-5B
Continued
5. Push in and turn control knob coun-
terclockwise to PILOT po-
sition. Press in control knob for
five(5) seconds.
Note:
You may be running this
heater for the first time after hook-
ing up to gas supply. If so, you may
need to press in control knob for 30
seconds. This will allow air to bleed
from the gas system.
6. Release downward pressure on con-
trol knob and turn clockwise
to OFF position.
7. Press in control knob and turn coun-
terclockwise past IGN to
PILOT (see Figure 19). This will
cause the piezo ignitor to spark and
light the pilot gas. Keep control knob
depressed for 10 seconds before re-
leasing. If needed, repeat steps 5
through 7 until pilot lights.
Note:
If pilot does not stay lit, refer
to Troubleshooting, pages 15 through
17. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot with
match. To light pilot with match, see
Manual Lighting Procedure, page 14.
8 . When pilot is lit, turn the control
knob to ON position (see Figure 21).
9. To select desired heating level, turn
the temperature setting knob coun-
terclockwise between 1 and
7 (see Figure 21).
Figure 20 - Pilot
Ignitor Electrode
Pilot Burner
Thermocouple
OFF
ON
PILOT
IGN
1
7
3
5
4
6
2
OFF
ON
PILOT
IGN
1
7
3
5
4
6
2
Figure 21 - Burner Patterns
Temperature Control
Setting Knob Knob FAS-3B FAS-5B
ON
OFF