VENTING INSTALLATION
INSTRUCTIONS
     
attempting installation.
These models are tested and approved for use with DESA (direct-
vent) pipe components and terminations.
The venting system must terminate on the outside of the structure
and can not be attached to a chimney or ue system serving a
separate solid fuel or gas burning appliance. A direct-vent appli-
ance must have its own venting system. DO NOT common vent
this appliance.
These models are approved to be vented either horizontally through
an outside wall or vertically through a roof or chase enclosure using
the following guidelines:
When venting system terminates horizontally on an outside
wall, you must install a standoff if the termination cap is to be
installed directly on a combustible nish such as vinyl, wood,
stucco, etc.
Never run the vent downward as this may cause excessive tem-
peratures which could cause a re.
Vent pipe air space clearances to combustibles are 1" on all sides
except on the horizontal sections, which requires 2" clearance
from the top of the pipe. Where the termination cap penetrates
a combustible wall, 1" air space clearance is required.
Snorkel terminations are required when minimum clearance to
grade cannot be met (see Figure 16 on page 11).
Have replace and selected vent components on hand to help
determine the exact measurements when elbowing or offsetting.
Always use wall restops when penetrating walls and restops
when penetrating ceilings or attic spaces.
If using a venting conguration of only horizontal venting with
no vertical run, a 1/4" rise for every 12" of run toward the ter-
mination is required.
WARNING: Read all instructions completely and
thoroughly before attempting installation. Failure to
do so could result in serious injury, property damage
or loss of life.

the warranty.

Wear gloves and safety glasses for protection
Use extreme caution when using ladders or when on roof tops
Be aware of electrical wiring locations in walls and ceilings
The following actions will void the warranty on your venting system:
Installation of any damaged venting component
Unauthorized modication of the venting system (Do not cut or
alter vent components)
Installation of any component part not manufactured or approved
by DESA
Installation other than as instructed by these instructions

must be vented directly to the outside. The venting
system must NEVER be attached to a chimney serving
a separate solid fuel burning appliance. Each direct-
vent gas appliance must use a separate vent system.
Do not use common vent systems.
WARNING: Vent pipe air space clearances to com-
bustibles are 1" on all sides except on the horizontal
sections, which require 2" clearances from the top of
the pipe. Where the termination cap penetrates a com-
bustible wall, 1" air space clearance is required.
INSTALLATION PLANNING
There are two basic types of direct-vent installation:
Horizontal Termination
Vertical Termination
Horizontal Termination Installation
IMPORTANT: Horizontal square terminations require only inner
portion of wall restop. Horizontal installations using round ter-
mination require exterior portion of wall restop available only in
vent kit HTK (see Figure 14, page 10).
1. Set the replace in its desired location and determine the route
your horizontal venting will take. Do not secure the replace
until all venting has been installed. Some installations require
sliding the replace in and out of position to make nal venting
connections. Figures 14 through 18 on pages 10 and 11 show
different congurations for venting with horizontal termina-
tion that will help you decide which application best suits your
installation. Check to see if wall studs or roof rafters are in the
path of your desired venting route. If they are, you may want
to adjust the location of the replace.