Desa CGS3124PA Water Heater User Manual


 
www.desatech.com
113101-01C
30
SPECIFICATIONS
18" Model 18" Model 24" Model 24" Model
(CGS2718PA) (CLD3018PTA) (CGS3124PA) (CLD3924PTB)
(SGS3124PA)
Btu (Variable) 16,000/27,000 18,000/30,000 16,000/31,500 20,000/39,000
Type Gas Propane/LP Propane/LP Propane/LP Propane/LP
Ignition Piezo Piezo Piezo Piezo
Manifold Pressure 8.0" W.C. 8.0" W.C. 8.0" W.C. 8.0" W.C.
Inlet Gas Pressure (in. of water)
Maximum 14" 14" 14" 14"
Minimum* 11" 11" 11" 11"
Shipping Weight 27 lbs. 27 lbs. 29lbs. 27 lbs.
* For the purpose of input adjustment
18" Model 18" Model 24" Model 24" Model
(CGS2718NA) (CLD3018NTA) (CGS3124NA) (CLD3924NTB)
(SGS3124NA)
Btu (Variable) 16,000/27,000 18,000/30,000 16,000/31,500 20,000/39,000
Type Gas Natural Gas Natural Gas Natural Gas Natural Gas
Ignition Piezo Piezo Piezo Piezo
Manifold Pressure 3.5" W.C. 3.5" W.C. 3.5" W.C. 3.5" W.C.
Inlet Gas Pressure (in. of water)
Maximum 10.5" 10.5" 10.5" 10.5"
Minimum* 5" 5" 5" 5"
Shipping Weight 27 lbs. 27 lbs. 29 lbs. 29 lbs
* For the purpose of input adjustment
4. The mounting clip must be a minimum of 3"
from bottom of fireplace to prevent crimping
of capillary. Once you have decided on a
location, clean the area thoroughly. Remove
the paper backing from the adhesive on back
of mounting clip. Press the clip into the new
location so that the thermostat sensing bulb
will be positioned vertically with the capil
-
lary at the bottom (see Figure 40). Slide the
thermostat sensing bulb into the clip.
IMPORTANT: Do not crimp capillary.
OPTIONAL POSITIONING
OF THERMOSTAT
SENSING BULB
Continued
Capillary
Thermostat
Sensing Bulb
Do Not Crimp
Capillary
Adhesive-
backed
Mounting Clip
Figure 40 - Positioning the Thermostat
Sensing Bulb in the Vertical Position
with the Capillary at the Bottom