Desa CGS2718PA Water Heater User Manual


 
www.desatech.com
113101-01C
20
Figure 27 - Pilot
Thermocouple
Ignitor
Electrode
Pilot Burner
VARIABLE CONTROL
OPERATION
The variable control valve can be set to any
heat setting and flame height desired, by simply
turning the control knob until that setting is
attained. Even the lowest setting provides re-
alistic, dancing yellow flames. Selecting higher
settings produces greater heat output. This
results in increased heating comfort.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1. Press in and turn control knob clockwise
to the HI position.
2. Turn control knob clockwise
to the
pilot position.
3. Press in control knob and turn clockwise
to the OFF position.
Shutting Off Burners Only (pilot stays lit)
1. Turn control knob clockwise
to the
HI position.
2. Press in and turn control knob clockwise
to the pilot position.
Propane/LP
Natural Gas
OPERATING HEATER
Continued
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not
use any phone in your building.
Immediately call your gas supplier
from a neighborʼs phone. Follow the
gas supplierʼs instructions.
If you cannot reach your gas supplier,
call the fire department.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand, donʼt
try to repair it, call a qualified service tech
-
nician or gas supplier. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a
qualified service technician to inspect the
appliance and to replace any part of the
control system and any gas control which
has been under water.
THERMOSTATICALLY-
CONTROLLED MODELS
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 5 under Lighting
Instructions, page 19.
2. Depress control knob and light pilot
with match.
3. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob. Now follow step 8 under
Lighting Instructions, page 19.
Thermocouple
Ignitor Electrode
Pilot Burner