OWNER’S MANUAL
BURNER FLAME PATTERN
Figure 20 shows a correct burner flame
pattern. Figure 21 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows yellow tipping of the flame. It
also shows the flame higher than 1/2 the
glass panel height.
NOTICE: Do not mistake orange
flames with yellow tipping. Dust
or other fine particles enter the
heater and burn causing brief
patches of orange flame.
WARNING: If yellow tipping
occurs, your heater could pro-
duce increased levels of carbon
monoxide. If burner flame pat-
tern shows yellow tipping, follow
instructions at bottom of this
page.
INSPECTING
BURNER
Continued
CORRECT FLAME PATTERN
AT HIGH POSITION
1/2 GLASS HEIGHT
If burner flame pattern is incorrect, as shown in Figure 21
turn heater off (see To Turn Off Gas to Appliance, page 10)
see Troubleshooting, pages 12 through 14
Figure 20 - Correct Burner Flame Pattern
(Model CGP6L will be lower due to lower input rating)
1/2 GLASS HEIGHT
INCORRECT FLAME PATTERN
AT HIGH POSITION
Yellow
Tipping
Figure 21 - Incorrect Burner Flame Pattern
(Model
CGP10L)
CLEANING AND
MAINTENANCE
ODS/PILOT AND BURNER
ORIFICE
Use a vacuum cleaner, pressurized air,
or small, soft bristled brush to clean.
CABINET
Air Passageways
Use a vacuum cleaner or pressurized air
to clean.
Exterior
Use a soft cloth dampened with a mild
soap and water mixture. Wipe the cabi-
net to remove dust.
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep
control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, etc.