Desa CGN30D Gas Heater User Manual


 
23
101826
TROUBLE-
SHOOTING
Continued
OBSERVED
PROBLEM
When control knob is
pressed in and turned
to the PILOT/IGN
position, there is
spark at ODS/pilot
but no ignition
ODS/pilot lights but
flame goes out when
control knob is
released
POSSIBLE
CAUSE
1. Gas supply turned off
or manual shutoff
valve closed
2. Control knob not
pressed in while being
turned to PILOT/IGN
position
3. Air in gas lines when
installed
4. ODS/pilot is clogged
5. Gas regulator setting is
not correct
1. Control knob not fully
pressed in
2. Control knob not
pressed in long enough
3. Manual shutoff valve
not fully open
4. Thermocouple connec-
tion loose at control
valve
5. Pilot flame not touch-
ing thermocouple,
which allows thermo-
couple to cool, causing
pilot flame to go out.
This problem could be
caused by one or both
of the following:
A) Low gas pressure
B) Dirty or partially
clogged ODS/pilot
6. Thermocouple dam-
aged
7. Control valve damaged
REMEDY
1. Turn on gas supply or
open manual shutoff
valve
2. Press in control knob
while turning to
PILOT/IGN position
3. Continue holding down
control knob. Repeat
igniting operation until
air is removed
4. Clean ODS/pilot (see
Cleaning and Mainte-
nance, page 22) or
replace ODS/pilot
assembly
5. Replace gas regulator
1. Press in control knob
fully
2. After ODS/pilot lights,
keep control knob
pressed in 10 seconds
3. Fully open manual
shut-off valve
4. Hand tighten until
snug, then tighten 1/4
turn more
5. A) Contact local
natural gas company
B) Clean ODS/pilot
(see Cleaning and
Maintenance, page 22)
or replace ODS/pilot
assembly
6. Replace thermocouple
7. Replace control valve
Continued