Desa CGD3924NR Gas Heater User Manual


 
22
103343
OPERATING
HEATER
Continued
TEMP
STATUS
HI
LO
MAN ON
AUTO OFF
Increases Room
Temperature
Decreases Room
Temperature
Turns Burners
On and Off
Shows Current
Operation Mode
Shows Temperature Setting
Allows Burners to be Turned
On and Off with the Hand-
Held Remote Unit.
Figure 22 - Thermostat Hand-Held Remote Control Unit Selections
The log heater will
automatically cycle between
pilot and the heat setting that
has been selected.
3. Use the STATUS button on the hand-held remote control unit to see the operation
mode being used and the temperature setting selected. A red light will come on
beside the operation mode being used when the status button is pressed.
4. To turn the burners off when operating in the MANUAL mode, press the OFF
button. If operating in the auto mode, press the manual button, then press the
OFF button The pilot will remain lit.
IMPORTANT:
To turn the pilot off, manually turn the control knob on the heater
to the OFF position or set remote selector switch to OFF position.
Thermocouple
Pilot Burner
Figure 23 - Correct Pilot Flame Pattern
Figure 24 - Incorrect Pilot Flame
Pattern
INSPECTING
BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 23 shows a correct pilot flame pattern. Figure 24 shows an incorrect pilot flame
pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the
thermocouple to cool. When the thermocouple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in Figure 24
turn heater off (see To Turn Off Gas to Appliance, page 21)
see Troubleshooting, pages 23 through 26
Thermocouple
Pilot Burner