Desa CGB35P Water Heater User Manual


 
15
100352
INSTALLING
HEATER
Continued
2
1
Glass
Panel
Lower Glass
Retaining
Channel
Figure 11 - Inserting Top Edge of
Glass Panel into Upper Glass
Retaining Channel
2
1
Glass
Panel
Lower Glass
Retaining
Channel
Upper Glass
Retaining
Channel
Lower Front
Access Area
Figure 12 - Inserting Glass into
Lower Retaining Channel
7. Lower glass into lower glass retaining channel (see Figure 12). Slide glass panel
all the way to the left side.
Note:
If you have chipped or cracked a glass panel during installation, do not
use. Contact DESA International’s Technical Service Department at 1-800-
323-5190 for a replacement glass panel.
8. Repeat steps 4 through 7 for all glass panels.
9. Reinstall glass guard. Reinstall lower front access panel of heater.
WARNING ICON G 001
CAUTION
Make sure you insert top edge of glass panels into the
upper glass retaining channel. Do not install glass
panels with top edge of glass in front of the upper glass
retaining channel. Glass panels will not automatically
go into the channel. You must guide the glass panels
into it. Incorrect installation will damage front of heater
due to excess temperatures.
Continued
6. Insert top edge of glass panel into the upper glass retaining channel (see Figure 11).
Hearth
Assembly
Lower Front
Access Area
Glass
Panel
Figure 10 - Inserting Glass Panels