Desa CCL3930PTB Water Heater User Manual


 
111160-01B
For more information, visit www.desatech.com
For more information, visit www.desatech.com
9
9
Figure 7 - Minimum Mantel Clearances Without Using Hood
Minimum Non-
Combustible
Material
Minimum Non-
Combustible
Material Height
Distances to
Underside of
Mantel
Top of Fireplace
Opening
Underside of
Mantel Shelf
Mantel Shelf
12"
8"
(A)
18"
8"
20"
14"
22"
17"
24"
20"
All minimum
distances are
in inches
Log Set
24"/30" Models
18" Model
2
1
/2
"
6"
8"
10"
MANTEL CLEARANCES
In addition to meeting noncombustible material clearances, you
must also meet required clearances between fireplace opening and
mantel shelf. If you do not meet the clearances in Figure 7, you will
need a hood.
Determining Minimum Mantel Clearance
If you meet minimum clearance between mantel shelf and top of
fireplace opening, a hood is not required (see Figure 7).
INSTALLATION
Continued
FLOOR CLEARANCES
A. If installing appliance on the floor level, you must maintain
the minimum distance of 14" to combustibles (see Figure 9).
B. If combustible materials are less than 14" to the fireplace, you
must install appliance at least 5" above the combustible floor-
ing (see Figure 10).
Determining Minimum Mantel Clearance When
Using a Hood
If minimum clearances in Figure 7 are not met, you must have a
hood. When using a hood there are still certain minimum mantel
clearances required. Follow minimum clearances shown in Figure
8 when using hood.
14"
Min.
Combustible
Material
Noncombustible
Material
Hearth
5"
Min.
Combustible
Material
Figure 10 - Minimum Fireplace Clearances Above Combus-
tible Flooring
Figure 8 - Minimum Mantel Clearances When Using Hood
Minimum Non-
Combustible
Material
8"
Min.
12" 15" 18"
All minimum
distances are
in inches
Log Set
18", 24", 30"
Models
20"
2
1
/2
"
6"
8"
10"
12"
Distances to
Underside of
Mantel
Hood
(GA6050, GA6052)
Top of Fireplace
Opening
Underside of
Mantel Shelf
Mantel Shelf
Figure 9 - Minimum Fireplace Clearances if Installed at Floor Level
(GA6050, GA6052,
and GA6053)
All Models
NOTICE: If your installation does not meet the mini-
mum clearances shown, you must do one of the
following:
operate the logs only with the flue damper open
raise the mantel to an acceptable height
remove the mantel
NOTICE: Surface temperatures of adjacent walls and
mantels become hot during operation. Walls and
mantels above the firebox may become hot to the
touch. If installed properly, these temperatures meet
the requirement of the national product standard.
Follow all minimum clearances shown in this manual.
INSTALLATION
Mantel Clearances
Floor Clearances