Desa RCLP100V Gas Heater User Manual


 
www.desatech.com
103908-01E 9
REMEDY
1. Check voltage to electrical
outlet. If voltage is good, check
heater power cord for breaks
2. Adjust motor/fan mount to
keep fan from hitting inside of
heater shell. Bend fan mount
if necessary
3. Replace fan. See Fan, page 7
4. Replace motor. See Motor
,
page 6
1.
Repeat installation and operation
instructions. See Installation,
page 4 and Operation, page 5
2. A) Check ignitor wire. Tighten
or reattach loose ignitor wire.
See Figure 10, page 8 for
ignitor wire location
B) Assure gap between ignitor
electrode and target plate is
0.13"/0.15" (3.3/3.8 mm). Do
not bend electrode. Doing so
may cause it to break
C) Replace ignitor electrode.
See Ignitor, page 8
D) Replace spark transformer.
See Spark Transformer, page 8
1. A) Refill tank
B) Provide additional and/or
larger tanks. See Propane
Supply, page 3
2. This can happen when running
heater in temperatures above
85°F (29˚C). Run heater in
cooler temperatures
3. Check heater inlet and outlet.
Remove any obstructions
4. Replace fan. See
Fan, page 7
5. Clean heater. See Mainte
-
nance, page 6
POSSIBLE CAUSE
1. No electrical power to heater
2. Fan hitting inside of heater
shell
3. Fan blades bent
4. Defective motor
1. User did not follow installa
-
tion or operation instructions
properly
2. No spark at ignitor. To test for
spark, follow step 8 under Ig-
nitor, page 8. If you see spark
at ignitor, have heater serviced
by qualified service person. If
no spark seen:
A) Loose or disconnected
ignitor wire
B) Wrong spark gap
C) Bad ignitor electrode
D) Bad spark transformer
1. Propane supply may be inad
-
equate
2. High surrounding air tem
-
perature causing thermal limit
device to shut down heater.
3. Restricted air flow
4. Damaged fan
5. Excessive dust or debris in
surrounding area
OBSERVED FAULT
Fan does not turn when heater is
plugged in
Heater will not ignite
Heater shuts down while run
-
ning
TROUBLESHOOTING
WARNING: Never service heater while it is plugged in, connected
to propane supply, operating, or hot. Severe burns and electrical
shock can occur.
WARNING: Use only in areas
free of high dust content.