PORTABLE FORCED AIR HEATERS
R
FUELS
Do not use heavy fuels such as No. 2 fuel oil
or No. 2 Diesel. Using heavy fuels will
result in:
clogged fuel filter and nozzle
carbon build up on spark plug
use of non-toxic anti-icer in fuel during
very cold weather
IMPORTANT:
Use a KEROSENE ONLY
container. Be sure storage container is clean.
Foreign matter such as rust, dirt, or water
will cause the flame-out control to shut
down heater. Foreign matter may also re-
quire you to clean fuel system often.
WARNING: Use only kerosene
or No. 1 fuel oil to avoid risk of fire
or explosion. Never use gaso-
line, naphtha, paint thinners, al-
cohol or other highly flammable
fuels.
ASSEMBLY
(FOR 100,000 AND 150,000
BTU/HR MODELS ONLY)
These models are furnished with wheels and
handles. Wheels, handles, and the mounting
hardware are found in the shipping carton.
Tools Needed
Medium Phillips Screwdriver
3/8" Open or Adjustable Wrench
Hammer
1. Slide axle through wheel support
frame. Install wheels on axle.
IMPORTANT:
When installing wheels,
point extended hub of wheels toward
wheel support frame (see Figure 3).
Figure 3 - Wheel and Handle Assembly, 100/150,000 Btu/Hr Models Only
Screw
Wheel
Support
Frame
Wheel
Cap Nut
Nut
Extended
Hub
Front Handle
Axle
Rear
Handle
Air Inlet
Fuel Tank
Flange
Hot Air
Outlet
2. Place cap nuts on axle ends. Gently tap
with hammer to secure.
3. Place heater on wheel support frame.
Make sure air inlet end (rear) of heater
is over wheels. Line up holes on fuel
tank flange with holes on wheel sup-
port frame.
4. Place front handle and rear handle on
top of fuel tank flange. Insert screws
through handles, fuel tank flange, and
wheel support frame. Attach nut finger
tight after each screw is inserted.
5. After all screws are inserted, tighten
nuts firmly.
VENTILATION
WARNING: Follow the mini-
mum fresh, outside air ventila-
tion requirements. If proper fresh,
outside air ventilation is not pro-
vided, carbon monoxide poison-
ing can occur. Provide proper
fresh, outside air ventilation be-
fore running heater.
Provide a fresh air opening of at least 2800
square cm (three square feet) for each
100,000 Btu/Hr rating. Provide extra fresh
air if more heaters are being used.
Example:
A 150,000 Btu/Hr heater requires
one of the following:
a two-car garage door raised 15 cm (six
inches)
a single-car garage door raised 23 cm
(nine inches)
two, 76 cm (thirty-inch) windows raised
31 cm (twelve inches)