Desa 90 Air Conditioner User Manual


 
6
099606
THEORY OF
OPERATION
The Fuel System: The air pump forces air through the air line. The air is then
pushed through the burner head nozzle. This air causes fuel to lift from the tank. A
ne mist of fuel is sprayed into the combustion chamber.
The Air System: The motor turns the fan. The fan pushes air into and around
the combustion chamber. This air is heated and provides a stream of clean, hot air.
The Ignition System: The electronic ignitor sends voltage to the spark plug.
The spark plug ignites the fuel and air mixture.
The Flame-Out Control System: This system causes the heater to shut down
if the ame goes out.
THEORY CUTAWAY
PFA/OV 003
Fan
Fuel
Filter
Air For Fuel
System
Air For Combustion
And Heating
Fuel
Spark
Plug
Combustion
Chamber
Intake
Air
Filter
Motor
Air Pump
Air line
To Burner
Electronic
Ignitor
Burner
Head
Clean
Heated
Air Out
Cool
Air
In
Output
Air
Filter
Nozzle
Fuel
Tank
FUELS
Do not use heavy fuels such as No. 2 fuel oil or No. 2 Diesel. Using heavy fuels
will result in:
clogged fuel lter and nozzle
carbon build up on spark plug
use of non-toxic anti-icer in fuel during very cold weather
IMPORTANT:
Use a KEROSENE ONLY container. Be sure storage container is
clean. Foreign matter such as rust, dirt, or water will cause the flame-out control to
shut down heater. Foreign matter may also require you to clean fuel system often.
!
WARNING
Use only kerosene or No. 1 fuel oil to avoid risk of re or
explosion. Never use gasoline, naphtha, paint thinners,
alcohol or other highly ammable fuels.
Figure 5 - Cross Section Operational View