17
102748
Fan
IMPORTANT:
Remove fan
from motor shaft before
removing motor from heater.
The weight of the motor
resting on the fan could
damage the fan pitch.
1. Remove upper shell (see
page 10).
2. Use 1/8" allen wrench to
loosen setscrew which
holds fan to motor shaft.
3. Slip fan off motor shaft.
4. Clean fan using a soft cloth
moistened with kerosene or
solvent.
5. Dry fan thoroughly.
6. Replace fan on motor
shaft. Place fan hub flush
with end of motor shaft
(see Figure 30).
7. Place setscrew on flat of
shaft. Tighten setscrew
firmly (40-50 inch-pounds/
4.5-5.6 n-m).
8. Replace fan guard and
upper shell.
Fan
Figure 29 - Fan, Motor Shaft, and Setscrew Location
Motor
Shaft
Fan
Figure 30 - Fan Cross Section
Setscrew
Motor
Shaft
Flush
Setscrew
Output Rating (kW) 8,8 20,5 26,4 44
(Btu/Hr) 30,000 70,000 90,000 150,000
Fuel Use Only Kerosene or No. 1 Fuel Oil
Fuel Tank Capacity
(U.S. Gal./Liters) 3.0/11.35 5.0/18.92 9.0/34.06 13.5/51.09
Fuel Consumption
(Gal. Per Hr./Liters Per Hr.) .23/.87 .49/1.85 .66/2.5 1.10/4.16
Electric Requirements 230 V/50 Hz (Same All Models)
Amperage (Normal Run) .8 1.0 1.58 1.2
Hot Air Output (CFM/CMM) 140/3.96 225/6.36 425/12 500/14.2
RPM 1425 2850 2850 2850
SPECIFICATIONS