Denso OFFICE PRO 12 Air Conditioner User Manual


 
6
INSTALLATION (cont.)
Plugging in the Unit
Check the prongs and surface of the power cord plug for dust/dirt. If
dust and/or dirt are present, wipe off with a clean, dry cloth.
Check the power cord, plug and prongs for damage or excess play.
If any damage or excess play is found, contact your MovinCool
reseller for repair.
For the Office Pro 24 model, fully insert plug into the A/C outlet and
rotate clockwise until it locks in place.
ƽWARNING:
If the power cord or plug is damaged, repair should only be
performed by qualified electrical personnel.
Do not connect/disconnect the power cord or attempt to
operate buttons with wet hands. This could result in electrical
shock.
ƽCAUTION:
•Office Pro 12 model ONLY: The AC outlet (115 VAC Single Phase,
60Hz) needs to be rated at 15A or higher. Do not share the outlet
with any other instrument or equipment.
•Office Pro 24 model ONLY: The AC outlet (208/230 VAC Single
Phase, 60Hz) needs to be rated at 20A or higher. Do not share
the outlet with any other instrument or equipment.
NOTE:
Make sure the AC outlet is free of dirt, dust, oil, water, or any
other foreign matter.
The Office Pro 12 model is equipped with an approved NEMA
plug configuration (L5-15). The appropriate outlet must be used
for this plug type.
The Office Pro 24 model is equipped with an approved NEMA
plug configuration (L6-20). The appropriate outlet must be used
for this plug type.