4
Adjusting the thermostat
Leave the thermostat at its highest setting until the room has
reached the required temperature.Then slowly turn the thermo-
stat slider back until you hear a click.The temperature selected in
this way will then be regulated automatically and kept constant by
the thermostat.
Frost protection function
With the thermostat slider in the position and a power selected,
the unit maintains the room at a temperature of about 5˚C, pre-
venting freezing with minimum energy consumption.
Cleaning and maintenance
Your oil filled raditor is absolutely free from maintenance, fully relia-
ble and will give many years of trouble free service. Wipe radiator
with soft damp cloth; do not use detergents or abrasives.
If necessary, use a vacuum cleaner to remove any built-up dirt.
Some models comes fitted with on anti-dust filter in the ventilation
system.
Remove periodically the filter from it seat and clean it (fig.3).
Attention: if you do not periodically clean the filter it could happen
that the fan stops working. If this occur, proceed as follows:
1. Turn the appliance off.
2. Remove the plug from the mains and let the appliance cool
down.
3. Remove the filter and clean it well.
4. Replace the filter.
Important notes
- Do not use your radiator close to bath, wash-basin, shower and
swimming pool.
- Do not use your radiator to dry laundry.
-Never place the power cable on top of the radiator while it is hot.
- Only use the radiator in an upright position.
- The heater must be positioned at least 50 cm from furniture or
other objects.
- If the power cable has been damaged, it must be replaced by the
manufacturer or the technical service centre or by a qualified per-
son so as to avoid all risks.
- In order to eliminate the radiator’s “new” smell,set it to maximum
power for at least 8 hours when used for the first time. During
this operation, the room in which the radiator is located must be
ventilated.
- It is perfectly normal for the radiator to make “creacking” sounds
when used for the first time. (or in the case of unfrequent use).
- The radiator must not be located immediately below a fixed soc-
ket-outlet.
- The body of this radiator is filled with a precise quantity of special
TRF1 15
*