DeLonghi PACA110-A120E Air Conditioner User Manual


 
134
5,25 in.
in the window
pane
in the wall: it is rec-
ommended that
you insulate a sec-
tion of the wall
using suitable insu-
lation.
in the wood-
en kickboard
of a French
window
F
Preparing for use
MAX 39 in
MAX100 cm
MIN 14 in
MIN 35 cm
SEMI-PERMANENT INSTALLATION
If required, your appliance can also be
installed semi-permanently (Fig. E).
Proceed as follows:
Drill a hole ø 5,25 inches (ø 134 mm) in an
outside wall or through a window pane.
Respect the dimensions and height of the
hole given in figure F and G.
Fit the wall flange into the hole.
Fit the air exhaust hose in the relevant
hose located on the rear side of the appli-
ance (fig. A page 5).
Fit the end of the hose to the wall
flange as shown in fig. G.
11
13
13
11
G
When the hose (9) is not fitted, the drilled hole
can be closed with the flange cap (11).
NOTE: When installing the air conditioner
semi-permanently, you should leave a door
slightly open as little as 1/2 “ (1 cm) to guar-
antee correct ventilation.
6
11,8 in
30 cm
11,8 in
30 cm
E
Keep the air hoses as short and free of
curves as possible to avoid constrictions.
As special tools are required for installa-
tion, we suggest you let install the
appliance by specialized personnel.