DeLonghi CT300 Air Conditioner User Manual


 
21
GENERAL DESCRIPTION
Pinguino is a very versatile air conditioner because it can operate both through water condensation as
well as air condensation.
The User may choose the operational method:
1) WATER FUNCTION - When excellent efficiency, lower energy consumption, and greater speed in
reaching the ideal climatic conditions are desired. This function is especially useful when the
appliance is just turned on and when the room temperature is quite warm.
When the water reserve (in the tank) has been used up, Pinguino automatically changes to the air
functioning mode.
2) AIR FUNCTION - This is the normal air conditioning function.
TECHNICAL DATA Tab.1
IDEAL OPERATING CONDITIONS Tab.2
ROOM TEMPERATURE 21 ÷ 35°C
ROOM HUMIDITY FACTOR BELOW 80%
WATER FUNCTION - AIR FUNCTION
Power supply voltage (V) 220...240 V ~
Frequency (Hz) 50
Electric power consumption (A) 3,85 - 4,45
Max.power consumption (air-condit.mode) (W) see rating label
*Max.power consumption (heating mode) (W) see rating label
Cooling capacity (Frig/h, W, Btu/h) see rating label
Cooling capacity (Frig/h, W, Btu/h) see rating label
Air flow capacity (m
3
/h) 360
Timer 24 h
Dimensions: width (mm) 560
height 735
depth 390
Net weight (kg) 44
Technical data subject to change without prior notice
* Model CT250H only
Note: When indoor temperature exceeds 32°C, the appliance should be operated with water.
IDEAL OPERATING HEATING CONDITIONS Tab. 3
max 5° C
ROOM TEMPERATURE