DAVIS 6322C Home Security System User Manual


 
Troubleshooting Cabled ISS Communication
8
Approximately one minute after power-up the outside relative humidity reading
should be displayed on the console.
5. If the ISS contains a UV sensor and/or solar sensor, press 2ND and then press RAIN
YR for current ultraviolet readings or press 2ND then press RAIN DAY for solar
radiation readings.
The UV reading displays in the center of the console. The solar reading displays in the
bottom right corner of the console display. UV and solar readings should be zero or
close to zero if the ISS is inside. Zero is a valid reading. Dashes(--) are displayed if no
data comes from the sensors.
6. Current weather data displayed on the console confirms communication.
Once the ISS has been powered and the console has successfully received accurate
readings from all the sensors, prepare the ISS for installation. Continue on to
“Preparing the ISS for Installation” on page 13 for more information.
If the communication problems still exist between the cabled ISS and the console, see
“Troubleshooting Cabled ISS Communication” below.
To ease the installation process of ISS at a location, disconnect the console cable from
the SIM. Remove the foam and slide the cable out through access port. Once a
location for both the ISS and the console has been arranged, reinsert the cable through
the access port, into the console connector, and reinsert the foam.
Troubleshooting Cabled ISS Communication
If the console is not receiving sensor readings from the ISS, please try the following
troubleshooting procedures.
Check the console to make sure it is being powered with the AC adapter supplied in
the Vantage Pro2 packaged box or three C batteries.
Note: The supplied adapter is a five-volt positive center AC to DC adapter. Other adapters may not work if
the voltage or adapter type is different.
Make sure the cable is firmly plugged into the ISS connector on the console.
Make sure that the console cable is firmly plugged into the correct connector on the
SIM.
Verify that all sensor cables are firmly plugged in.
An LED indicator light on the SIM flashes each time the ISS transmits, which is
about once every 2.5 seconds. If the LED remains dark, there is a problem with the
ISS transmitter. Call Technical Support. See “Contacting Davis Instruments” on
page 27.
See “SIM Board Display and Contents” on page 30 for information on locating the LED
indicator light and the DIP switches.
Note: If the LED is flashing rapidly, call Technical Support. See “Contacting Davis Instruments” on
page 27 for more information.
If the console is still not receiving readings, ensure that the console is in Setup Mode and
reboot the console by disconnecting the AC power adapter from the console and
removing the console batteries for at least 30 seconds. If the console is still not displaying
sensor readings from the ISS, please contact Davis Technical Support.
07395.249 Manual ISS Installation_RevE_Final_Print.pdf 10 4/7/2008 1:44:49 PM