Danby DPAC10010 Air Conditioner User Manual


 
AIR CONDITIONING
NOTE: The exhaust hose must be properly vented outdoors during air
conditioning mode.
1) Press the POWER SWITCH key (Fig. A) to switch on the unit, and the
previous set temperature will be shown in the temperature display area of the
control panel.
2) Press the MODE key (Fig. B) until the COOL indicator light illuminates on the
control panel (Fig.C). Each depression of the MODE key will advance to a
different mode setting (Cool- Dehumidifier-Fan)
3) Press the appropriate increase or decrease buttons (Fig. D1 & D2) to
select a suitable operating temperature setting. Temperature settings are
adjustable between 16°C (61°F) to 32°C (89°F).
4) Press the FAN key (Fig. E) to select the desired fan speed setting (Auto-High-
Med.-Low). Your selection will appear on the control panel (each depression of
the fan key will advance to a different setting).
• Cooling stops automatically when the set temperature is achieved. Cooling
resumes when the room temp. rises above the “set” temperature level.
DEHUMIDIFIER:
NOTE: The exhaust hose does NOT have to be vented outdoors during
dehumidifier mode.
1) Press the ON/OFF key pad to switch the unit on (Fig. A)
2) Press the MODE key (Fig. B) until the DRY indicator illuminates on the
control panel (Fig. G).Each press of the MODE key will advance to a different
mode setting (Cool-Dehumidifier-Fan).
3) If room temperature is 25°C (77°F), fan speed can be adjusted. Press the Fan
key (Fig. E) to select the desired FAN SPEED setting. Your selection will
appear on the contol panel. Each depression of the fan key will advance to a
different fan speed (High- Med.- Low) as shown in Fig. F. Otherwise, fan
speed is fixed to “low”.
Note: THE WARM AIR EXCHANGE HOSES MUST VENT INSIDE THE
ROOM WHEN USING DEHUMIDIFY MODE, NOT OUTSIDE AS IT DOES
WHEN COOLING.
FAN:
NOTE: During Fan Mode, the exhaust hose does NOT have to be vented
outdoors.
1) Press the POWER SWITCH key pad to switch the unit on (Fig. A).
2) Press the MODE key (Fig. B) until the FAN indicator illuminates on the
control panel (Fig. C). Each press of the MODE key will advance to a different
mode setting (Cool- Dehumidifier-Fan).
3) Press the FAN Key (Fig. E) to select the desired FAN SPEED setting. Your
selection will appear on the control panel. Each press of the fan key will
advance to a different fan speed (High- Med- Low) as shown in Fig. F.
Fig. A
Fig. B
Fig. C
Fig. E
Fig. F
OPERATION (cont’d)
Fig. D1
Fig. D2
6
IMPORTANT: The drain
hose must be installed during
dehumidifier mode.
Drain Hose (79” / 200cm)
Fig. G