Danby DAC7077EE Air Conditioner User Manual


 
Electrical Specifications
1. All wiring must comply with local and national
electrical codes and must be installed by a
qualified electrician. If you have any questions
regarding the following instructions, contact a
qualified electrician.
2. Check available power supply and resolve any
wiring problems BEFORE installing and
operating this unit.
3. This 115V air conditioner uses 10.1 or less
(depending on model) nameplate amps and may
be used in any properly wired, general purpose
household receptacle. See Table 1 for
specifications for individual branch circuit.
4. For your safety and protection, this unit is
grounded through the power cord plug when
plugged into a matching wall outlet. If
you are not sure whether your wall outlet is
properly grounded, please consult a
qualified electrician.
5. The wall outlet (3-pin) must match the plug (3-
pin) on the service cord supplied with the unit.
DO NOT use plug adapters. See Table 2 for
receptacle and fuse information. DO NOT USE
"REGULAR" EXTENSION CORDS WITH THIS
UNIT. If it is necessary to use an extension cord
to connect your air conditioner, use an approved
"air conditioner" extension cord only. (available at
most local hardware stores)
6. The rating plate on the unit contains electrical
and other technical data.
Table 1:
Suggested Individual Branch Circuit
Nameplate Amps AWG Wire Size*
4.9 to 10.1 14
AWG- American Wire Gage
* Based on copper wire at 60 °C temperature rating.
Table 2:
Receptacle and Fuse Types
Rated Volts 125
Amps 15
Wall Outlet
Fuse Size 15
Time Delay Fuse Plug Type
(or circuit breaker)
3