Danby DAC5210M Air Conditioner User Manual


 
LOCATION
A) This room air conditioner is designed to fit
easily into a single or double hung window. However,
since window designs vary, it may be necessary to
make some modifications for safe, proper installation.
B) Make sure window and frame are structurally
sound and free from dry and rotted wood.
C) For maximum efficiency, install the air conditioner
on a side of the house or building which favours more
shade than sunlight. If the unit is in direct sunlight, it
is advisable to provide an awning over the unit.
D) Provide sufficient clearance around the cabinet to
allow for ample air circulation through the unit (See
Fig. 2). The rear of the unit should be outdoors and
not in a garage nor inside a building. Keep unit as far
away as possible from obstacles/obstructions and at
least 30” above the floor or ground. Curtains and
other objects within a room should be prevented from
blocking the air flow.
E) Be certain the proper electrical outlet is within
reach of the installation. Use only a single outlet
circuit rated at 15 amps. All wiring should be in
accordance with local and national electrical codes.
F) DO NOT install unit where leakage of
combustible gas is suspected. Your air conditioner
may fail to operate in air containing oils (including
machine oils), sulfide gas, near hot springs, etc.
Awning
Fence,
wall, or
other
obstacle
Ground
Side
Obstruction
20”
Min
30”
Min
20”
Min
12” Min
Fig. 2
NOTE: Your unit is designed to evaporate condensation
under normal conditions. However, under extreme
humidity conditions, excess condensation may cause
basepan to overflow to the outside. The unit should be
installed where condensation run-off cannot drip on
pedestrains or neighboring properties.
INSTALLATION INSTRUCTIONS (cont’d)
4
3/8” screws
“L” shaped
mounting bracket
“U” shaped Channel
(Factory Installed)
Fig. 3
Slide down into tabs
Shutter tabs
Shutter
Shutter frame
Fig. 4
1) Assembly of the Upper Channel to Cabinet.
• “L” Shaped Top Channel: Install the “L” shaped channel to the
top of the cabinet as shown in Fig. 3, using four (4) 3/8” screws.
2) Assembly of the Side Curtains to Cabinet.
• Extend the shutter from the shutter frame and slide it into the
shutter tabs on the side channel of the air conditioner, as shown in
Fig. 4.
• Slide the shutters into the top (“L” Shaped) and bottom (“U”
Shaped) channels. The shutters are identified (on frame) as left
and right.
3) Completing the Installation
• Cut the foam (non adhesive) sealing strip to fit the area of the