Danby ADR556RH Dehumidifier User Manual


 
10
Factory Default Setting:
When the unit is first connected to a power supply, the
electronic circuit board will automatically default to the
following factory settings;
Mode: Dehumidifier
Humidity Set Air Value:60% RH
Fan Speed: = Low
NOTE: In the event of a power failure or the unit is
switched ‘Off’, the most recent settings are retained and
restored once the power is switched “On”/resumed.
IMPORTANT NOTE: Depending on the ambient humidity
or temperature conditions (subject to the last operating
mode), when power is restored or switched ‘On’ the dehu-
midifier or heater may not start automatically under the
factory or custom (
see page 7
) default setting. This is an
indication that the ambient temperature or RH% level of
the surrounding environment is lower than the current
default setting and it may be necessary to select a lower
set temperature or RH% value.
DRY OR HEAT MODE SELECTION:
1. The unit does not have to be switched on (opera-
tional) to select/set a program. All programs can be
selected with the unit in the “off” position.
2. Press the MODE button until the Dry or Heat symbol
is shown in the mode area of the display.
Note: Each time the MODE button is pressed, the setting
will alternate between DRY (dehumidifier) mode, FAN
(only) and HEAT mode.
3. Press the or cursor buttons to select the
desired Temperature or RH% operating value.
Note: During dehumidifying mode (only) to select CONTIN-
UOUS operation, press the button until the symbo l
- - appear in the SET AIR display. During CONTINU-
OUS mode operation, the humidistat (control) will be by-
passed and the compressor will operate non-stop regard-
less of humidity conditions.
FAN SPEED SELECTION:
4. Press the fan symbol on the keypad. Each time the
button is pressed, the mode selection will alternate
between "High Fan" and "Low Fan" speed options.The
fan speed you select will appear in the LED display;
either a 4 blade fan symbol for ‘high fan’ or a 3 blade fan
symbol for ‘low fan’ will be shown in the display area.
5. When all settings are complete, press the I/O button to
start the selected operation (MODE) and the blue opera-
tion light will illuminate.
FAN ONLY MODE SELECTION:
1. Press the MODE button until the fan blade symbol is
shown in the mode area of the display.
2. Press the "Fan” symbol on the keypad. Each time the
button is pressed, the mode selection will alternate
between "High Fan" and "Low Fan" speed options.
3. When all settings are complete, press the on/off button
to start fan mode operation and the blue operation light
will illuminate.
AIR FILTER:
Your dehumidifier features a removable Air Filter. This fil-
ter is located at the front of the unit (behind the front air
intake grill) The air filter plays an important role in helping
to reduce (minimize) dust/dirt particles from the surround-
ing environment. A blocked/clogged air filter reduces air
flow impacting negatively on operating efficiency.To main-
tain maximum operating efficiency; The filter must
be checked and cleaned regularly. (every 2 weeks) More
frequent cleaning may be required depending upon
indoor air quality.
IMPORTANT: Never operate the unit without the air
filter in place.
AIR FILTER REMOVAL:
1. Locate the air filter (handle) tab on the upper right side
of the front air intake grill and slide-out the filter to
the right.
2. Clean the filter thoroughly using a vacuum cleaner or
wash using luke warm water and mild detergent.
Dry thoroughly before re-installing.
3. To re-install the air filter, slide the filter back inside
the tracks until it snaps (locks) into position.
Operating Instructions
Capacité de déshumidification (Pintes/Litres) 55/26
Alimentation électrique 115 Volts / 60 Hz
Consommation d’énergie (watts)
• Déshumidification 502
• Chauffage 1200
Intensité nominale
• Déshumidification 4,6
• Chauffage 8.0
Circulation d’air – Vitesse de ventilateur haute / basse (pi. cu. /min)(L/min) 178,5 / 145
Type de réfrigérant R22
Capacité du réservoir d’eau (litres / pintes) 5,3 / 11,2
Niveau de bruit en fonctionnement (dB A) 50
Dimensions (largeur/hauteur/profondeur) 13-3/4 po x 30-1/2 po x 13-3/16 po
Poids net (kg/lb) 25 / 55,1
Circuit d’alimentation électrique - Spécifications
1. Tout câblage doit être réalisé par un électricien
qualifié, en conformité avec les prescriptions des\
codes national et local régissant les installations
électriques. Pour toute question au sujet des instru
tions qui suivent, contacter un électricien qualifié.
2. AVANT l’installation et AVANT l’utilisation de cet
appareil, contrôler les caractéristiques de la source
d’électricité, et résoudre tout problème affectant le
câblage.
3. Pour la sécurité et la protection des utilisateurs, cet
appareil est mis à la terre lorsqu’il est branché sur une
prise de courant de même configuration que la fiche
de branchement. En cas de doute quant à la qualité
de la mise à la terre de la prise de courant, consulter
un électricien qualifié. NE JAMAIS UTILISER UN
CÂBLE DE RALLONGE NI UN ADAPTATEUR SI LA
CONFIGURATION DE LA FICHE DE
BRANCHEMENT NE CORRESPOND PAS À
CELLE DE LA PRISE DE COURANT.
4. La plaque signalétique de l’appareil est située sur la
paroi (arrière) du cabinet. On y trouve les
caractéristiques électriques et techniques spécifiques
de cet appareil.
5. Pour éviter les risques de blessures corporelles, on
doit toujours débrancher l’appareil de la source
d’électricité avant d’entreprendre des travaux de
nettoyage ou d’entretien.
17
NOTE: Les spécifications sont sujettes aux changements sans préavis (pour l'amélioration des produits).
Spécifications de l’appareil:
ADR556RH