DESCRIPTION
Signal from Remote Controller put in only Control Data Signal at Micom Terminal of Number 5, which is gotten
field of Carrier (38KHz) from Receive Module. Signal Wave repeat third as following Fig 5-1.
But in Secondary Wave Custom Code is Reversed Face.
Remote Controller(4)
LEADER CODE
CUSTOM
CODE
0.56ms 0.56ms
1.12ms 2.25ms
bit 0 bit 1
DATA
CODE
9ms 4.5ms 16bit 16bit
Fig 5-2
BIT STRUCTURE
Fig 5-1