Daewoo DOC-091RH Air Conditioner User Manual


 
7
Your window kit has been designed to fit most standard
Vertical and horizontal window applications, However, it
may be necessary for you to improvise/modify some aspects
of the installation procedures for certain types of window.
Please refer to Fig. 11 & Fig. 11a for minimum and maximum
window openings.
Window Kit Installation
Horizontal
window
Window Slider Kit
Minimum:67.5cm(2.22ft).
Maxmum:123cm(4.04ft).
Window Slider Kit
Minimum:67.5cm(2.22ft).
Maxmum:123cm(4.04ft).
Horizontal
window
This unit is equipped with a internal water tank, two full-safe
switch mechanisms, one is used to control the water pump
drainage, the other is used to monitor the water level inside
the internal water tank. When the water level reaches a
predetermined level, the full-safe switch mechanism is
activated. The digital display shows P1 and the water full
indicator light illuminates. Carefully move the unit outside,
remove the rubber blockage from the back drainage hole
and drain the water off. The unit will continue operating
properly.
Drain Tank Safety Feature
MAINTENANCE
1) BE SURE TO UNPLUG THE UNIT BEFORE CLEANING.
2) DO NOT USE GASOLING, THINNER OR OTHER CHEMICALS TO CLEAN THE UNIT.
3) DO NOT WASH THE UNIT DIRECTLY UNDER A TAP OR USING A HOSE. THE ELECTRICAL
CAUE DANGER.
4) IF THE POWER CORD IS DAMAGED, IT SHOULD BE REPAIRED BY MANUFACTURE OR ITS
AGENCY.
IMPORTANT:
1 AIR FILTER
- Clean the air filter at least once every two weeks to
prevent inferior fan operation because of dust.
- Removal
Pull out the filter cover and remove the air filter from the
filter cover.
- Cleaning
Wash the air filter by immersing it gently in warm water
OO
(about 40 C/104 F) with a neutral detergent. Rinse the
filter and dry it in a shady place.
- Mounting
Attach the air filter to the filter cover using the attachment
hooks on the inner surface of the cover. Put the filter cover
back to the unit.
2 UNIT ENCLOSURE
- Use a lint-free cloth soaked with neutral detergent to clean
the unit enclosure. Finished by a dry clean cloth.
Fig.11
Fig.11a
Fig.12