Creda TPR2-1000W Electric Heater User Manual


 
Wall Mounting
IMPORTANT -The wall brackets supplied with the appliance
must be used. The heater should be positioned observing
the minimum clearances stated around the heater - see
Fig.1.
DO NOT locate the heater immediately below a fixed socket
outlet or connection box.
1. Remove wall mounting bracket from the back of the
heater by depressing the spring latch at the top of
each bracket - see Fig. 2.
2. Fix the wall bracket securely to the wall through the
four screw holes provided.
3. Present the heater to the wall bracket, and engage
lower slots in the back with bracket.
4. Raise the heater to its upright position and push
the heater onto the bracket to engage the top
latch.
Thermostat Operation
The heater is fitted with an adjustable thermostat enabling
the room temperature to be controlled by adjusting the setting
accordingly. The
*
setting represents a room temperature
of approximately 5°C and may be used for protection
against frost. Higher temperature settings range from 1 to
6 (max.) creating a maximum room temperature of
approximately 30°C.
Switch on the heater and turn the thermostat knob to the
position corresponding to the required temperature for the
room. The heater will then maintain the room temperature at
the chosen level, provided that the correct size of heater has
been selected for the room to be heated.
NOTE - Should your heater fail to come on when the
thermostat knob is at a low setting, this may be due to the
room temperature being higher than the thermostat setting.
Operation - TW Models - Thermostat and Timer
Control of Output and Temperature (see Fig. 5)
The slide switch on the timer unit controls the electricity
supply to the heating elements on TW models.
Access to the controls
The controls cover on your heater has a latch which may
be locked shut if desired using a small bladed screwdriver
- see Fig. 3.
To open the cover insert the blade of the screwdriver in the
small slot and rotate a quarter of a turn clockwise to
disengage the latch. The cover may then be hinged back
towards the wall for access to the controls.
Fig. 3
Operation - W models - Thermostat only
Control of Output and Temperature (see Fig. 4)
The isolating switch in the fixed wiring should be used to
switch the product ON and OFF. When ON the product will
be controlled by the thermostat.
Thermostat Operation
- see above.
Using the Timer
The heater must be connected to the electricity supply for the
timer to operate. Set the timer by rotating the dial clockwise
until the correct time of day is indicated opposite the datum
mark (located at centre front of the timer - see Fig. 5).
'OFF’ Position
Set the timer switch to | position. The timer operates but
the heater will not output any heat, as the electricity supply to
the heating elements has been disconnected.
Manual Operation
Set the timer switch to , position. The heater will now
operate continuously under the control of the thermostat
- see 'Thermostat Operation' above.
Fig. 4
Fig.
2
Fig.5