Louisville Tin and Stove VFM204 Electric Heater User Manual


 
INTRODUCTION – CONT’D.
For your protection this heater is equipped with an Oxygen Depletion Sensor (ODS) pilot system. Never operate heater if
ODS has been damaged or tampered with as this could expose you to Carbon Monoxide (a colorless, odorless gas) that
could result in injury or death. Early signs of Carbon Monoxide poisoning resemble influenza, with headaches, dizziness,
or nausea. If you develop these symptoms GET FRESH AIR AT ONCE. Turn off heater and call a qualified serviceman to
check heater. Some people are more affected by Carbon Monoxide than others: Including pregnant women, persons with
a heart or lung disease, anemia, those under the influence of alcohol, and those at high altitudes.
OPERATION
Infrared heaters “heat like the sun” with almost instantaneous, safe, clean burning “waves” of infrared heat. Like the sun,
they must “see” the object to be heated. Make sure they are installed away from furniture or any other object which
might block the infrared “waves”. The Cozy thermostatically controlled units offer the additional benefit of automatically
cycling the heating to maintain just the right room temperature. Ventfree gas room heaters are designed strictly for
“supplemental” room heat use and should never be installed as “sole source heating”.
ROOM HEATER SPECIFICATIONS
Your room heater comes packed in a single carton. Before installation, check the rating plate to verify that the Model
Number is correct and that the room heater is equipped for the type gas you intend to use.
SAFETY INSTRUCTIONS
1) Keep burner and control compartment clean.
2) Due to high temperatures, the heater should be located out of traffic and away from furniture and draperies.
3) Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns
or clothing ignition.
4) Young children should be carefully supervised then they are in the same room with this heater.
5) Do not place clothing or other flammable material on or near the heater.
6) Any safety screen or guard removed for servicing must be replaced prior to operating the heater.
Page 3
MODEL NUMBER MANUAL MODELS THERMOSTAT MODELS
NATURAL GAS VFM63 VFM103 VFM203 VFM303 VFT101 VFT201 VFT301
PROPANE GAS VFM64 VFM104 VFM204 VFM304 VFT102 VFT202 VFT302
TYPE CONTROL MAN. MAN. MAN. MAN. T-STAT T-STAT T-STAT
BULB BULB BULB
HEIGHT 22-1/2” 22-1/2” 22-1/2” 22-1/2” 22-1/2” 22-1/2” 22-1/2”
WIDTH 11-1/2” 14-9/16” 20-11/16” 26-13/16” 14-9/16” 20-11/16” 26-13/16”
DEPTH 7” 7” 7” 7” 7” 7” 7”
INPUT (BTU/HR.) 5,500 10,000 LO / 10,000 LO / 10,000 10,000 20,000 30,000
HI / 20,000 MED./20,000
HI / 30,000
Gas Supply Line Size ½” ½” ½” ½” ½” ½” ½”
Optional CVF Blower NO NO YES YES NO YES YES
Optional Floor Stand NO YES YES YES YES YES YES
Bathroom Installation YES NO NO NO NO NO NO
Bedroom Installation YES YES NO NO YES NO NO
Piezo Ignitor YES YES YES YES YES YES YES
Shipping Weight 16 LB. 22 LB. 30 LB. 35 LB. 22 LB. 30 LB. 35 LB.
As applicable:
1. An unvented room hetaer having an input rating of more than 10,000 Btu per hour shall not be installed in a bedroom
or bathroom; or
2. An unvented room heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom.