Louisville Tin and Stove 5000 BTU Electric Heater User Manual


 
Side Valve Concealer
4˝-16˝ Vent System (Standard)
Bottom Valve Concealer
STANDARD ITEMS OPTIONAL ACCESSORIES
1 Watt = 3.413 BTU
SPECIFICATIONS
Form No. BBT 20M 3/04
Standard Vent 1-1/2˝ Direct Spark Ignition
I.D. Seal Module Self-Diagnosing
Mounting Template, 24 Volt Wall T-Stat Kit, Power Cord
and Flex Connector with Ball Valve
Vent Weather Seal Kit with
2˝ I.D. Seal
Vent Riser Kit
NOTE: Conversion Kits are available for Nat or L.P. Gas (specify existing model no.)
Minimum
Model
Input Type Type Gas Center Wall Wall Max Wall Min Ship
No. BTU/Hr. Watts Gas Control AFUE Width Depth Height Conn. Voltage of Vent Opening Thickness Thickness Weight
to Floor
BBT53 5,000 1,465 Nat. 24 Volt 73.0% 48˝ 5-3/8˝ 9-3/8˝ 3/8˝ 115V 7-7/16˝ 2-1/2˝ 16˝ 4˝ 46 lbs
BBT54 5,000 1,465 L.P. 24 Volt 73.0% 48˝ 5-3/8˝ 9-3/8˝ 3/8˝ 115V 7-7/16˝ 2-1/2˝ 16˝ 4˝ 46 lbs
BBT103 9,000 2,930 Nat. 24 Volt 80.4% 72˝ 5-3/8˝ 9-3/8˝ 3/8˝ 115V 7˝ 2-1/2˝ 16˝ 4˝ 62 lbs
BBT104 9,000 2,930 L.P. 24 Volt 80.4% 72˝ 5-3/8˝ 9-3/8˝ 3/8˝ 115V 7˝ 2-1/2˝ 16˝ 4˝ 62 lbs
5,000 BTU
(Face Off)
48˝ (122 cm)
9,000 BTU
(Face Off)
72˝ (183 CM)
Inside Finish
Outside Finish