Louisville Tin and Stove CF504R Furnace User Manual


 
CONTENTS
Contents……………………………………………........... 2
Introduction…………………………………………. 2
Specifications……………………………………….. 2
Safety Rules………………………………………… 3
Helpful Installation Information……………….........…. 3
Connecting the Vent……………………………....…..… 3,4
Combustion and Ventilation Air...................................... 5
Furnace Location………………………………….....…. 6
Rough-In Instructions…………………………..…..…. 6,7
Installation……………………………………….......….. 8
Controls…………………………………………........….. 9
Pilot Flame Adjustment…………………………......….. 9
Lighting & Re-Lighting Instructions……………….. 10,11
Operation………………………………………….....…. 12
Terminal Block Wiring Diagram……………….....…… 13
Manual Reset…………………………………....…….. 13
Maintenance Instructions…………………….……… 13
Wiring Diagram……………………………….....…….. 14,15
Side & Rear Discharge Kits……………………...……16,17
Trouble Shooting Chart…………………………..….. 18,19
Repair Parts (break down)………………………..….. 20-24
Repair Parts List…………………………………....…. 21-25
Warranty………………………………………….....…. 27
INSTALLER MUST LEAVE THESE INSTRUCTIONS WITH THE CONSUMER, HAVE THEM
COMPLETE, AND RETURN THE WARRANTY CARD.
INTRODUCTION
THIS IS A GAS-FIRED, GRAVITY VENTED WALL FURNACE THAT WILL OPERATE SAFELY AND PROVIDE AN
EFFICIENT SOURCE OF HEAT WHEN INSTALLED, OPERATED AND MAINTAINED AS RECOMMENDED IN THESE
INSTALLATION AND OPERATING INSTRUCTIONS. READ THESE INSTRUCTIONS THOROUGHLY BEFORE
INSTALLING, SERVICING, OR USING THE APPLIANCE. IF YOU DO NOT UNDERSTAND ANY PART OF THESE
INSTRUCTIONS CONSULT LOCAL AUTHORITIES, OTHER QUALIFIED INSTALLERS, SERVICE AGENCIES, THE
GAS SUPPLIER, OR THE MANUFACTURER.
COUNTERFLOW WALL FURNACE SPECIFICATIONS
Your counterflow wall furnace is packed in a single carton that also includes thermostat, thermostat wire, and insulated staples.
The thermostat, wire, and staples are packed in the burner compartment and are accessible by removing the burner access door.
While the burner access door is open, check the rating plate to verify that the model number is correct and that the wall furnace
is equipped for the type gas you intend to use.
Vent Approx.
Model Type Type BTU/HR. Size Gas Blower Shipping
Number Control Gas Input (Oval) Inlet Finished Dimensions Speed Amps CFM Weight
MODELS WITH LOW-BTU STANDING PILOT
CF353C 24 Volt Nat. 35,000 4” ½” 14-5/16”Wx10¼”Dx78-5/8”H 1 1.95 320 95 Lbs.
CF354C 24 Volt L.P. 35,000 4” ½” 14-5/16”Wx10¼”Dx78-5/8”H 1 1.95 320 95 Lbs.
CF503C 24 Volt Nat. 50,000 4” ½” 14-5/16”Wx10¼”Dx81-5/16”H 2 2.25 440 104 Lbs.
CF504C 24 Volt L.P. 50,000 4” ½” 14-5/16”Wx10¼”Dx81-5/16”H 2 2.25 440 104 Lbs.
CF653C 24 Volt Nat. 65,000 4” ½” 14-5/16”Wx10¼”Dx87-5/16”H 2 2.25 440 107 Lbs.
CF654C 24 Volt L.P. 65,000 4” ½” 14-5/16”Wx10¼”Dx87-5/16”H 2 2.25 440 107 lbs.
MODELS WITH INTERMITTENT IGNITION
CF357C 24 Volt Nat. 35,000 4” ½” 14-5/16”Wx10¼”Dx78-5/8” H 1 2.2 320 95 Lbs.
CF358C 24 Volt L.P. 35,000 4” ½” 14-5/16”Wx10¼”Dx78-5/8”H 1 2.25 320 95 Lbs.
CF557C 24 Volt Nat. 55,000 4” ½” 14-5/16”Wx10¼”Dx87-5/16”H 2 2.5 440 107 Lbs.
CF558C 24 Volt L.P. 55,000 4” ½” 14-5/16”Wx10¼”Dx87-5/16”H 2 2.55 440 107 Lbs.
Page 2