Louisville Tin and Stove 90N65A Furnace User Manual


 
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.
\. This appliance has a pilot which must be lighted by department.
hand. When lighting the pilot, follow these instruc-
tions exactly. C.
BEFORE LIGHTING smell all around the appliance
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the
floor. D.
WHAT TO DO 1FYOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch; do not use any
phone in your building.
hrnnediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
LIGHTING INSTRUCTIONS
STOP! Read the information on the safety label.
Set thermostat to lowest setting.
Remove the floor grille.
Place the furnace key on the control rod, push do,a_
slightly and turn clockwise _ to "ALL OFF".
_P,N]_ NOTE: Conn-ol
rod cannot be
turned from
"PILOT" to "ALL
O OFF" unless the
control rod is
pushed dm_al
slightly.
Use only your hand to push in or turn the gas control tfllob
Never use tools. If the tfllob will not push in or turn by hand
don't try to repair it, call a qualified service technician. Forc_
or attempted repair may result in a fire or explosion.
Do not use this appliance if any part has been under warm
hmnediately call a qualified service technician to inspect th_
appliance and to replace any part of the control system am
any gas control which has been under water.
ALL OFF
5. Wait five (5) minutes to clear out any gas. Then
smell for gas, including near the floor. If you smell
gas, STOP! Follow "B' in the information on the
safety label. If you don't smell gas, go to the next
step.
6. Remove the sight glass assembly from the opening
on top of the heat exchanger.
7. Locate the pilot burner looking down through the
sight glass opening.
8. Turn the control rod counterclockwise _ until
the pointer is on "PILOT".
Pilot
Bumer
Pilot is located
on the side of
and toward
control end
of burner
9. Locate the red piezo igniter button beside the control rod
10. Press down on the control rod with the furnace key
hmnediately begin a series of pushing and releasing th_
red piezo igniter while observing the pilot through the sigh
glass opening, continue to spark until pilot is lit or use th_
lighter md with match. Continue to hold the control roc
down tbr about one (1) minute after the pilot is lit. If it goe_
out, repeat steps 4 through 10.
,, If control rod does not pop up when released, STOP anc
immediately call your service technician or gas supplier.
Ifthe pilot will not stay lit after several tries, turn the contro
rod to "OFF" and call your service technician or ga_
supplier.
11. Replace the sight glass assembly and turn the control roc
countercloclcvvise _ to "BURNER" position. Remow
furnace key and replace the floor grille.
12. Set thermostat to desired temperature.
I'O TURN OFF GAS TO APPI3ANCI,
1. Set the thermostat to it's lowest setting.
2. Allow floor grille to cool, then remove.
3. Place furnace key on control rod, push slightly and
turn ctoc_vise /"X to "ALL OFF". Do not tbrce.
€. Replace floor grille.
Page 11