Coway CHP-03AL Water System User Manual


 
StateofCalifornia
DepartmentofPublicHealth
Water Treatment Device
Certicate Number
08 - 1867
DateIssued:June24,2008
Trademark/Model Designation Replacement Element(s)
MachCHP-03AR WJNF11Neo-SenseFilter
WJMF11-50ROMembraneFilter
WJCF11-POSTPost-carbonFilter
WJFF7FineFilter
WJCC-02CeramicFilter
Manufacturer:WoongjinCowayCoLTD
Thewatertreatmentdevice(s)listedonthiscerticatehavemetthetestingrequirementspursuanttoSection
116830oftheHealthandSafetyCodeforthefollowinghealthrelatedcontaminants:
Microbiological Contaminants and Turbidity Inorganic/Radiological Contaminants
None Arsenic(Pentavalent)
1
Barium
Cadmium
Chromium(Hexavalent)
Chromium(Trivalent)
Lead
Nitrate/Nitrite
2
Radium226/228
Selenium
Organic Contaminants
VOCs
Alachlor Endrin Simazine
Atrazine Ethylbenzene Styrene
Benzene EDB 1,1,2,2-Tetrachloroethane
Carbofuran Haloacetonitriles(HAN) Tetrachloroethylene
CarbonTetrachloride Bromochloroacetonitrile Toluene
Chlorobenzene Dibromoacetonitrile 2,4,5-TP(Silvex)
Chloropicrin Dichloroacetonitrile TribromoaceticAcid
2,4-D Trichloroacetonitrile 1,2,4-Trichlorobenzene
DBCP Haloketones(HK) 1,1,1-Trichloroethane
o-Dichlorobenzene 1,1-Dichloro-2-Propanone 1,1,2-Trichloroethane
p-Dichlorobenzene 1,1,1-Trichloro-2-Propanone Trichloroethylene
1,2-Dichloroethane Heptachlor Trihalomethanes(THMs)
1,1-Dichloroethylene HeptachlorEpoxide Bromodichloromethane
cis-1,2-Dichloroethylene Hexachlorobutadiene Bromoform
trans-1,2-Dichloroethylene Hexachlorocyclopentadiene Chloroform
1,2-Dichloropropane Lindane Chlorodibromomethane
cis-1,3-Dichloropropylene Methoxychlor Xylenes
Dinoseb Pentachlorophenol
Rated Service Capacity: 229 gal Rated Service Flow: 0.07 gpm
Do not use with water that is microbiologically unsafe or of unknown quality, without adequate disinfection
before or after the system.
1
Claimsforarsenicreductionshallonlybemadeonwatersuppliesmaintainingdetectableresidualfreechlorineatthe
reverseosmosis(RO)systeminlet.Watersystemsusinganin-linechlorinatorshouldprovideaminimumof1minute
chlorinecontacttimebeforetheROsystem.
2
Thissystemisacceptablefortreatmentofinuentconcentrationsofnomorethan27mg/Lnitrateand3mg/Lnitritein
combinationmeasuredasNandiscertiedfornitrate/nitritereductiononlyforwatersupplieswithapressureof280kPa
(40psig)orgreater.Asamplingandanalysistestkitfornitrateisprovidedforcheckingtheperformanceofthissystem.
Frequentanalysisisencouraged.