Costar 12SIR Carbon Monoxide Alarm User Manual


 
Instruction Manual: COSTAR® 12SIR, 12V System CO Alarm
QGI P/N 099-0066-01 REV 10/26/01
Page 6 of 7
for proper operation and the RED LED will flash 4-6 times. At completion of the self-test, the alarm will sound 2 alarm patterns. The
alarm then resumes normal operation.
9.8 This box contains two self-adhesive labels. You should write the telephone numbers of the emergency service provider and
a qualified technician in the space provided on the labels. Place one label next to the alarm, and the other label near a source of fresh
air where you plan to gather after the alarm indicates the presence of carbon monoxide.
9.9 Attention Installer: Please leave this manual at residence for user's information.
10.0 ALARM SIGNALS
10.1 NORMAL OPERATION
RED L.E.D. flashes once every 30 seconds, indicating that the alarm is powered and active.
10.2 ALARM CONDITION
RED LED turns "on" for 2 seconds and "off" for 4 seconds with 4 short beeps for 1 second and 5 seconds of silence. The
RED LED will illuminate and the alarm relay will be energized (N.O. or N.C.). Pushing and holding the test/reset button for 3
seconds will silence the alarm for about 4 minutes. After 4 minutes, the alarm will once again sound until the unsafe CO
concentration is reduced.
10.2.1 Connected zone should be programmed for 24 hour monitoring and immediate response for hazardous levels of carbon
monoxide.
10.2.2 Alarm RELAY output 1 form 'C' dry contacts (non-latching) current capacity is 100 microAmp - 0.1A
10.3 TROUBLE CONDITION
The detector self-tests every 10 minutes. The detector will beep and the Indicator/Test button will flash twice every 30
seconds if a fault is detected. This is an indication of a malfunction and that the detector requires immediate servicing.
10.3.1 Trouble RELAY output
1 form 'C' dry contacts (non-latching) current capacity is 100 microAmp – 0.1A
Trouble relay connection to panel is optional.
11.0 MAINTENANCE
CLEANING YOUR ALARM:
11.1 Keep your CO alarms clean–do not wash.
11.2 To clean your alarm remove it from the mounting bracket as outlined in section 9.2.
11.3 You can clean the interior of your alarm by using your vacuum cleaner hose and vacuuming through the openings around the
perimeter of the alarm.
11.4 The outside can be wiped with a cloth.
11.5 After cleaning, reinstall your alarm and test your alarm by using the TEST button.
11.6 Test your alarms weekly and repair or replace them when they no longer function. As with any electronic product, alarms
have a limited life and alarms that do not work cannot warn you.
WARNING: Do not use any household cleaning agents, paints, varnishes or any other chemical on your 12SIR alarm.
NOTE: REGULAR TESTING IS RECOMMENDED.
12.0 PERIODIC ALARM TESTING
Test the alarm weekly for proper operation by pushing the test button until a short beep is heard (approximately three seconds).
Release the button. The alarm will then test itself for proper operation and the RED LED light will flash 4-6 times. At completion of
the test, the alarm will sound 2 patterns. The alarm then resumes normal operation.
13.0 SERVICE AND WARRANTY
If after reviewing this manual you feel that your CO Alarm is defective in any way, do not tamper with the unit. Before returning the
device, call Quantum Group's customer service line at 1-800-432-5599 to receive a return merchandise authorization (RMA) number.
Once an RMA number has been issued, return the product along with a proof of purchase that includes a date. Please enclose a note
describing the problem and send it to:
7737 Kenamar Court
San Diego, CA 92121-2425
Or call us toll free 1-800-432-5599
E-mail address: CustomerService@QGinc.com