Costar 9RV Carbon Monoxide Alarm User Manual


 
Step A: Step B: Step C: Step D:
Ceiling Mounting Wall Mounting Battery Installation Installation / Removal
Figure 2: Installation Instructions
6.4 As described in Figures 1-2, attach the mounting plate on the wall. Be sure the “UP FOR WALLMOUNT-
ING” text and arrow are facing up. Use the screws and anchors provided to secure the mounting plate.
6
.5 The battery is INSTALLED REVERSED FOR SHIPPING. Remove and reinstall the battery in the correct
orientation as noted on the inside of the battery door. When installing the battery, align the “+” and “-” battery
terminals on the correct contacts. The alarm will beep once indicating proper battery installation.
WARNING: BATTERY IS REQUIRED FOR ALARM OPERATION AND DETECTION OF CARBON
MONOXIDE. IF NO BATTERYIS INSTALLED, THE BATTERY DOOR WILLNOT CLOSE EASILY
A
ND THE UNIT WILLNOT ATTACH TO THE MOUNTING BRACKET.
6.6 Align marks on the edge of the trim plate with those on the alarm. Twist the alarm in the direction indicated by
the “ON” arrow on the alarm cover (see step D) until it locks in place.
6
.7 To make your carbon monoxide alarm tamper resistant, a locking pin has been provided in the bag with the
screws and anchors. Using this pin will deter children and others from removing the alarm from the mounting
plate. To use the pin, insert it into the hole in the side of the alarm after the
a
larm has been installed on the mounting plate (see fig. 3). Note the tamper
resist pin will have to be removed in order to change the battery. Using long
nose pliers pull the pin out of the hole, it is now possible to remove the
a
larm from the mounting plate. Test alarm immediately following installa-
tion and weekly therafter for proper operation by pushing the test button
until a short beep is heard (approximately three seconds). Release the
b
utton. The alarm will then test itself for proper operation and the RED
LED will flash 5 times. At completion of the self-test, the alarm will sound 2 patterns. The alarm then resumes
normal operation.
6
.8 This box contains two self-adhesive labels. You should write the telephone numbers of the emergency service
provider and a qualified technician in the space provided in the labels. Place one label next to the alarm, and
the other label near a source of fresh air where you plan to gather after the alarm indicates the presence of
c
arbon monoxide.
7.0 ALARM SIGNALS
7.1 NORMAL OPERATION---RED LED flashes once every 30 seconds, indicating that the alarm is powered and
active.
7.2 A
LARM CONDITION---RED LED turns “on” for 2 seconds and “of
f” for 4 seconds with 4 short beeps for 1
second and 5 seconds of silence. Pushing and holding the test/reset button for 3 seconds will silence the alarm
for about 4 minutes. A
fter 4 minutes, the alarm will once again sound until the unsafe CO concentration is
reduced.
7.3 TROUBLE/SERVICE CONDITION---The detector self-tests every 10 minutes. The detector will beep and the
Indicator/Test button will flash once every 30 seconds if a fault is detected. This is an indication of a malfunc-
tion and that the detector requires immediate servicing.
7.4 LOW BATTERY---REDLED flashes and horn chirps once every 30 seconds for a minimum of (7)days.
Replace battery when this signal occurs
8.0 MAINTENANCE – CLEANING YOUR ALARM:
WA
RNING:
Do not use any household cleaning agents, paints, varnishes or any other chemical on your 9RV
alarm.
8.1 To clean your alarm remove it from the mounting bracket as outlined in Section 6.2.
8.2 You can clean the interior of your alarm by using your vacuum cleaner hose and vacuuming throughthe open-
ings around the perimeter of the alarm.
8.3 The outside can be wiped with a clean towel. Test your alarms weekly and repair or replace them when they no
longer function. As with any electronic product, it has a limited life. Alarms that do not work cannot warn you.
8.4 After cleaning, reinstall your alarm and test your alarm by using the TEST button.
NOTE: REGULAR TESTING IS RECOMMENDED.
9.0 BATTERYREPLACEMENT
IF
T
AMPER RESIST
ANT
PIN HAS BEEN USED, REFER
T
O STEP
6.7 UNDER INST
ALLATION
INSTRUCTIONS FOR REMOV
ALINSTRUCTIONS. (see Figure 3)
9.1 To replace the battery remove the alarm from the mounting plate by rotating the alarm in the direction of the
“OFF” arrow on the cover. (see Figure 2, Step D).
9.2 The COSTAR
®
Model 9RV CO Alarm uses one (1) 9 volt alkaline battery. A fresh battery should last for one
year under normal operating conditions.
They can be purchased anywhere batteries are sold, such as your local
hardware store.
9.3 USE ONLYTHE FOLLOWING 9 VOLTBATTERYFOR CO ALARM REPLACEMENT.
Alkaline type: DURACELL
MN1604
WARNING USE ONLYTHE BATTERY SPECIFIED. USE OFDIFFERENT BATTERIES MAYHAVE
ADETRIMENTALEFFECT ON THE CO ALARM. CONSTANT EXPOSURE TO HIGH OR LOW
HUMIDITY
MA
Y
REDUCE BA
TTERYLIFE. CHECK THE BATTERY MANUFACTURERS SPECI-
FICATIONS FOR PROPER OPERATING CONDITIONS.
Note:
Most batteries are not rated below -20°C or above 54°C
10.0 PERIODIC ALARM TESTING
T
est the alarm weekly for proper operation by pushing the test button until a short beep is heard (approxi
-
mately three seconds). Release the button. The alarm will then test itself for proper operation and the RED
LED will flash 4-6 times.
At completion of the self-test, the alarm will sound 2 patterns. The alarm then
resumes normal operation.
1
1.0 SERVICE AND WARRANTY
If after reviewing this manual you feel that your CO Alarm is defective in any way, do not tamper with the
unit. Before returning your device, call Quantum Group’s customer service line at 1-800-432-5599 to receive a
return merchandise authorization (RMA) number
. Once an RMA
number has been issued, return product along
a note describing the problem and send it to:
7737 Kenamar Court
San Diego, CA92121-2425
LIMITED WARRANTY
COSTAR
®
Model 9RV
Quantum Group Inc. offers you this limited warranty on your new carbon monoxide alarm, including all of its
component parts. This limited warranty extends solely to the original end-user purchaser of this product, provided
y
our purchase was made from an authorized vendor. Transfer or resale of this product will automatically terminate
warranty coverage.
Q
uantum Group Inc. warrants the enclosed carbon monoxide alarm to be free from defects in materials and work-
manship under authorized use and service, as specified in the owner’s manual, for a period of six (6) years from
the date of manufacture. During the initial two (2) year period commencing with the date of manufacture, any
r
epair or replacement shall be made without charge. During the latter four (4) years of the warranty period, any
repair or replacement shall be made at a charge to the purchaser not to exceed the manufacturer’s cost of repair or
replacement. All replaced items become the property of Quantum Group Inc.
QUANTUM GROUP INC. MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, EXCEPTAS
REQUIRED BY LAW, AND IN NO CASE FOR ADURATION LONGER THAN THAT OF THIS WRITTEN
W
ARRANTY, EXCEPT AS REQUIRED BYLAW, INCLUDING, BUTNOT LIMITED TO, ANYWARRANTY
OF MERCHANTABILITY OR FITNESS FOR APARTICULAR PURPOSE OR AGAINST INFRINGEMENT,
OR ANY EXPRESS OR IMPLIED WARRANTYARISING OUT OF TRADE USAGE OR OUT OF ACOURSE
O
F DEALING OR COURSE OF PERFORMANCE. Quantum Group Inc. has not authorized any other party to
extend any other warranties in connection with the sale of the product, and will not accept responsibility for any
statements, representations, or warranties made by any other person.
This limited warranty does not cover: (1) 9 volt alkaline battery; (2) products which have been improperly installed,
repaired, maintained, modified, or which have been subjected to misuse, abuse, accident, neglect, exposure to fire,
w
ater, or excessive changes in climate or temperature, or combined with non-Quantum Group Inc.-approved acces-
sories; (3) physical damage caused from use other than normal and proper operation or handling, as specified in the
owner’s manual; (4) cosmetic damage; (5) products on which warranty stickers or product serial numbers have been
r
emoved, altered, or rendered illegible; (6) the cost of installation, removal or reinstallation.
QUANTUM GROUP INC. SPECIFICALLY DISCLAIMS LIABILITYFOR ANYAND ALL DIRECT, INDI-
R
ECT, SPECIAL, GENERAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING, BUTNOT
LIMITED TO, LOSS OF PROFITS OR ANTICIPATED PROFITS ARISING OUT OF USE OF OR INABILITY
TO USE THE PRODUCT.