Cooper Lighting SRR Indoor Furnishings User Manual


 
3.
Universal
(4x)
2.
assembly
Pan head screw
If possible, remove ceiling tile from grid to facilitate fixture
1.
Fixture
installation.
bracket
Using cut out dimensions provided on page four(4), cut
#10-32 x3/8"
appropriate size opening in ceiling tile.
Ceiling tile
Insert fixture assembly into cut out in ceiling tile.
1.
Using cut out dimensions provided on page four(4), cut
hole into dry wall and feed power wire to hole.
2.
After removing fixture head, loosen #10-32 x3/8" Pan head
screws and remove cover plate closest to power feed.
3.
Knock out appropriate hole for conduit and attach as shown
on page three(3).
4.
Replace cover plate and secure with #10-32 x3/8" Pan head
screws and press fixture housing into hole in drywall.
(ceiling grid)
Pan head screws
Universal brackets
1.
(4x)
3/8".
(2x)
Loosely reattach brackets to both sides of fixture housing.
2.
Press brackets flush to ceiling tile and secure using #10-32 x
Replacing brackets on fixture housing
#10-32 x 3/8"
1.
Prior to pushing fixture into hole in drywall, tie off fixture
housing to structure using saftey wire(by others) as show on
page three(3).
2.
Gently push fixture housing into hole and tighten 1/4-20 x 1
1/2" Pan head screw from inside fixture housing to tighten
drywall bracket around drywall.
3.
Connect appropriate wires from fixture head and ensure all
wires are properly matched.
4.
Replace fixture head assembly on keyhole screws and
tighten.
1/4-20 x1 1/2"
Pan head screw
Safety wires
(by others)
(4x)
Securing the fixture in drywall
Fixture housing
(drywall)
Wiring the fixture
Conduit from
Cover plate
power source.
(by others)
#10-32 x3/8"
Pan head screws
(2x)
Do not
work must meet local/national codes and be
: Before starting any work ensure
Vault w/ visor
These installation instructions are valid with the above Ametrix styles.
mount fixtures vertically.
Roundel w/ visor
Installation Instructions
3.
Sheet 2 of 4
Visor and Non-Visor
ADY071459 REV B (ECN80481)
3.
Warning
that all sources of power are turned off. All
performed by a certified electrician.
C-Scroll w/ visor
2.
Small, INDOOR
SRR
(S
emi-
R
ecessed
, R
emote ballast
)
2.
Securing fixture to ceiling tile
Semi-recessed fixtures shown without thermal protectors