PHOTOMETRICS
P5-M32T-E5SRC
Test No. H36117
Lamp: 26W PLT
Lumens: 1800
Cutoff: 75°
Spacing: 1.1
Efficiency: 32.4%
Unit LPW: 22.43
Unit Number: PN5-M32T-E5SRC
Candelas
Vertical CD
Angle
90 0
85 0
75 5
65 37
55 82
45 142
35 202
25 256
15 294
5 309
0 311
Luminance
Degree cd/m
2
85
˚
0
75
˚
1410
65
˚
6266
55
˚
10183
45
˚
14384
4'6"
5'6"
6'6"
8'0"
10'0"
12'0"
5'0"
6'6"
7'6"
9'6"
11'6"
14'0"
15
10
7
5
3
2
Cone of Light
Distance to Initial Nadir Beam
Illuminated Plane Footcandles Diameter
Notes and Formulas:
Luminance: To convert cd/m
2
to footlamberts, multiply by 0.2919
Cone of Light:
• Footcandle and CU multiplier: clear x 1.0, Haze x .95, Gold x .90, Black x .65, Warm Haze x .90
• Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
• Footcandle values are initial. Apply appropriate light loss factors where necessary.
CU Notes/Formulas:
• maintained illuminance=lamp lumens x CU x light loss factors
room area
• total number of luminaires=total room area x maintained illuminance
lamp lumens x CU x light loss factors
• CU data based on 20% effective floor cavity reflectance.
80% 70% 50% 30% 0%
70 50 30 10 50 10 50 10 50 10 0
38 38 38 38 38 38 36 36 34 34 32
36 35 34 33 34 33 33 32 32 31 29
34 32 31 29 32 29 30 28 29 28 26
32 29 27 26 32 29 30 28 29 28 26
30 27 25 23 26 23 26 22 25 22 21
28 24 22 20 24 20 23 20 23 20 19
26 22 20 18 22 18 21 18 21 18 17
24 20 18 16 20 16 19 16 19 16 15
22 18 16 14 18 14 18 14 17 14 14
21 17 15 13 17 13 16 13 16 13 12
19 16 13 12 15 12 15 12 15 12 11
Ceiling Reflectance
Wall Reflectance
Room Cavity Ratio
0
1
2
3
4
5
6
7
8
9
10
Coefficient of UtilizationZonal Lumen Summary
Zone Lumens %Lamp %Luminaire
0-30 230 12.8 39.5
0-40 356 19.8 61.1
0-60 539 30.0 92.6
0-90 582 32.4 100.0
90-180 0 0.0 0.0
0-180 582 32.4 100.0
Distribution