Cooper Lighting P4SP-MX SE Indoor Furnishings User Manual


 
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
09/17/2008 2:35:44 PM
Specifications and Dimensions subject to change without notice.
ADF020747
PHOTOMETRICS
ORDERING INFORMATION
ACCESSORIES
SHIPPING INFORMATION
DIVM
Candela
Angle Along II 45
o
Across
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
7110 7110 7110
7021 6991 7081
6689 6693 6748
6168 6164 6219
5469 5460 5545
4573 4551 4104
3532 3084 2363
2321 1382 947
998 448 444
24 100 131
257 226 217
672 417 417
1093 684 634
1478 1016 899
1800 1298 1218
2064 1613 1466
2243 2149 1892
2351 2339 2363
2376 2376 2376
Coef
ficients of Utilization
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0
1
2
3
4
5
6
7
8
9
10
Zonal Lumen Summary
Zone Lumens %Lamp %Fixture
0-30
0-40
0-60
0-90
90-180
0-180
||
DIVM-296PG
Standard Ballast
F96PG17/CW Lamps
15300 Lumens
Spacing criterion:
(II) 1.3 x mounting
height, () 1.3 x
mounting height
Efficiency 84.4%
Test Report:
DIVM296PG.IES
LER = FI-59
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $4.07
5605 18.3 21.7
9275 30.3 35.9
16531 54.0 64.0
20185 66.0 78.2
5627 18.4 21.8
25811 84.4 100.0
96 96 96 96 92 92 92 92 84 84 84 76 76 76 69 69 69 66
88 84 81 78 84 80 77 75 74 71 69 67 65 64 61 60 59 56
80 74 68 64 76 70 66 61 65 61 57 59 56 53 54 52 50 47
73 65 58 53 70 62 56 51 57 52 48 52 48 45 48 45 42 40
67 57 50 45 64 55 49 44 51 45 41 47 42 39 43 39 36 34
61 51 44 39 58 49 42 38 45 40 35 42 37 33 38 35 31 29
57 46 39 34 54 44 38 33 41 35 31 38 33 29 35 31 28 26
52 42 34 29 50 40 33 29 37 31 27 34 29 26 32 28 25 23
49 38 31 26 46 36 30 26 34 28 24 31 27 23 29 25 22 20
45 35 28 23 43 33 27 23 31 26 22 29 24 21 27 23 20 18
43 32 25 21 41 31 25 21 29 23 20 27 22 19 25 21 18 16
Tandem
Blank=4' Length
8T=8' Length
Series
DIVM=Apertured
Reflector
DCIVM=Closed Top
Reflector
SAMPLE NUMBER: DIVM-296PG-120V-EB81-U
Number
of Lamps
2 Lamps
(Not included)
Voltage
(1)
120V=120 Volt
277V=277 Volt
347V=347 Volt
Options
GL=Single Element Fuse
GM=Double Element Fuse
Emergency=EM Installed
NOTES:
(1)
Products also available in non-US voltages and frequencies for internation-
al markets.
Specifications & dimensions subject to change without notice. Consult your Cooper
Lighting Representative for availability and ordering information.
Wattage (Length)
48VHO=110W (48") VHO
96VHO=185/215W (96") VHO
96PG=185/215W (96") PG
Ballast Type
(1)
EB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
EB8
/PLUS=T8 Electronic Instant Start.
High Ballast Factor >1.13. Total
Harmonic Distortion < 20%
ER8
=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
EB2
=T12 Electronic Rapid Start.
No. of Ballast
1, 2 or 3
No. of
Ballast
1, 2 or 3
No. of Ballast
1, 2 or 3
No. of Ballast
1 or 2
Options
RIF1=Radio Interference
Suppressor
6-3/18 SJT-C&P-515P=Cord
& Plug (120V)
6-3/18 SJT-C&P-
L715P=Cord & Plug (277V)
PI/CPI=Plug-In Option
TILW=Tandem In-Line
Wiring Option (Consult
TILW Option Catalog Page)
POX=Porlux Finish
(See options & accessories)
Packaging
U=Unit Pack
4B=4 Bulk
(Order Separately)
A1B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling
(Use 2 per fixtur
e)
ATG-4=Tong Hanger (Use 2 per fixture)
SCF=Fixed Stem Set (Specify Length)
SCS=Swivel Stem Set (Specify Length)
SCA=Adjustable 48" Stem Set
AYC-Chain/Set-U=Chain Hanger Set (Use 1 set per fixture)
WG/DI-4FT-U
2
=Wire Guard
WGG/DI-4FT-U
2
=Wire Gym Guard
MECL-DI/SL-48-U=Metal Egg Crate Louver
MECL-DI/SL-96-U=Metal Egg Crate Louver
DI2=Long Connector
CEP=Closed End Plate
(Additional Accessories Available. See Options and Accessories Section).
DIVM-248PG
1
26 lbs.
DIVM-296PG
1
41 lbs.
Catalog No. Wt.